IKEA DATID HGA4K User Manual - Page 10

Browse online or download pdf User Manual for Hob IKEA DATID HGA4K. IKEA DATID HGA4K 16 pages. Lagan
Also for IKEA DATID HGA4K: Instructions (4 pages), Manual (24 pages), Assembly Instructions Manual (20 pages), Manual (12 pages)

IKEA DATID HGA4K User Manual
ENGLISH
The connection of the cooktop to the gas pipe
network or gas cylinder must be made by
means of a rigid copper or steel pipe with fit-
tings complying with local regulations, or by
means of a continuous surface stainless steel
hose complying with local regulations.
If you see any abnormalities do not repair
the pipe, contact local After Sales Service
(refer to the Service chapter).
The connection must be installed correctly,
fixed into hob connection pipe. Otherwise it
will cause leakage of gas
Warning! Once the installation is
complete, check the perfect seal of every
pipe fixing. Use soapy water, never flame.
Electrical connection
Before connecting, check that the nominal volt-
age of the appliance stated on the rating
plate, corresponds to the available supply
voltage. Also, check the power rating of the
appliance and ensure that the wire is suitably
sized to suit the appliance power rating (refer
to the Technical data chapter).
The rating plate is located on the lower casing
of the hob.
The appliance is supplied with a connection
cable. This has to be provided with a proper
plug, able to support the load marked on the
identification plate. To connect the plug to the
cable, follow the recommendation given in fol-
lowing figure.
Replacement of the connection cable
The replacement of the connection cable re-
quires the specific equipment of a technician.
In this case, only cable type H05V2V2-F T90
must be used. The cable section must be suit-
able to the voltage and the working temper-
ature. The yellow/green earth wire
approximately 2 cm longer than the brown (or
black) phase wire
The plug has to be fitted in a proper socket. If
connecting the appliance directly to the elec-
tric system, it is necessary that you install a
double pole switch between the appliance
and the electricity supply, with a minimum gap
of 3 mm between the switch contacts. The dou-
ble pole has to be of a type suitable for the
required load in compliance with the current
rules.
The connection cable has to be placed in order
that, in each part, it cannot reach a 90 °C tem-
perature. The blue neutral cable must be con-
nected to the terminal block marked with "N".
The brown (or black) phase cable (fitted in the
terminal block contact marked with "L") must
always be connected to the live phase.
2
1
(previous figure).
10
1
2
must be