NOTE: the power supply cable must be long
enough to permit its upward extraction. To
secure the hob, use the brackets provided
with it. Fit the brackets into the relevant
bores shown by the arrow and fasten them
by means of their screws in accordance with
the thickness of the worktop.
Make sure that the outlet is near the product
to install. So, if the cable that came with the
product is not long enough, you will need to
replace it with another one having the same
features but with the right length.
Adjustment to different type of gas
WARNING
This operation must be performed by a
qualified technician.
If the appliance is intended to operate with
a different gas from the gas type stated on
the rating plate and information label on
the top of the hob, change the injectors.
Remove the information label and keep it
with the instructions booklet.
Use pressure regulators suitable for the gas
pressure indicated in the Instruction.
- The gas nozzles must be changed by After
Sales Service or a qualified technician.
- Nozzles not supplied with the appliance
must be ordered from After Sales Service.
- Adjust the minimum setting of the taps.
NOTE: when liquid petroleum gas is used
(G30/G31), the minimum gas setting screw
must be tightened as far as it will go.
IMPORTANT: should you experience
difficulty in turning the burners knobs,
please contact the After Sales Service for
the replacement of the burner tap if found to
be faulty.
Replacing the injectors (see paragraph
"injector table")
- Remove grids (A).
- Extract burners (B).
- Using a socket spanner of the appropriate
size unscrew the injector (C), unscrew the
injector to be replaced.
- Replace it with the injector suitable for the
new type of gas.
- Re-assemble the injector in (D). Before
installing the hob, remember to affix
the gas calibration plate supplied with
the injectors in such a way that it covers
the existing information relating to gas
calibration.
D
C
29
A
B