Airflow Hi-flow 2L Instruction Manual - Page 12
Browse online or download pdf Instruction Manual for Measuring Instruments Airflow Hi-flow 2L. Airflow Hi-flow 2L 14 pages.
The pump reservoir can be removed with ease for
cleaning purposes by undoing the screw located at
the front of the pump, depressing the front and
allowing the reservoir to be moved downwards (care
should be taken as there may be water in the reservoir).
Note: The pump does not need to be removed from its
fixings to clean the reservoir. The quick release outlet
barb can be removed very easily by twisting and
pulling out.
The pump should be flushed through with anti-
bacterial wash every 6 months to avoid sludge build
up in the pump reservoir. Note: Contractors should
satisfy themselves that any chemicals used are
suitable and will not damage the pump.
If the supply cord is damaged the pump must be
switched off until the supply cord is replaced by a
suitably qualified person to avoid a hazard.
Note: Servicing and maintenance should be carried
out by a competent person.
For further help please contact Airflow
Developments.
12