Technical data
Nominal voltage:
Permitted input voltage:
Aver. power consumption:
Data storage:
Internal clock:
Reader type:
Frequency of reading field:
Control elements:
Display elements:
Host interface:
Dimensions
1
2
3
4
93 mm (3.66")
Typical application
Power supply
Network
Turnstile
Valid as from July 30
, 2013 • Technical data subject to modifications without notice!
th
2
DB_GAT-ACCESS6100--EN_11.indd • PartNo.: 860279
12/24 VDC (SELV - safety extra-low
voltage)
10 to 28 VDC
3 W
Internal EEPROM memory for
configuring and booking memory,
data preservation min. 10 years
Data preservation approx. 12 h
(Gold-Cap)
See order information
13.56 MHz
- 4 function keys
- RFID reader
- Full graphics monochrome display
(LCD) with white LED background
lighting, resolution 128 x 64 pixels,
visible area 50 x 25 mm
- RFID reader (illuminated)
- Acoustic signal
- 4-segment LED display with
different colours
Ethernet 10/100 MBit/s
24 mm (0.94")
6
5
33 mm (1.3")
GAT Access 6100
RFID data carriers
Signal input:
Signal output:
Connection terminals:
Housing material:
Dimensions:
Permitted ambient temperature: -10 to +55°C
Storage temperature:
Relative humidity:
Protection type:
Protection class:
Weight:
Environment class
based on VDS 2110:
1. 4-segment LED display
2. Monochrome display (LCD)
3. Function keys
4. Illuminated, round scan field
5. Device back part
6. Device upper part
1 x optocoupler (configurable)
- Input voltage: 0 to 30 VDC
U
< 2 VDC, U
> 6 VDC
Low
High
- Input current: 4.5 mA
1 x relay (configurable NO/NC)
- Switching voltage: max. 30 VAC/DC
- Continuous current: max. 2 A
- Switching power: max. 60 VA
0.5 to 1.5 mm
2
- Upper part: plastic PMMA
- Back part: plastic PC-ABS
93 x 107 x 33 mm
-20 to +70°C
20 to 80%, non-condensing
IP 54
III
0.2 kg
II (conditions in indoor areas)
www.gantner.com