All-Freezer Specifications
•
Product Shipping Weight (approx.) – 229 Lbs.
An electrical supply with grounded three-prong receptacle is
•
required. The power supply circuit must be installed in accordance
with current edition of National Electrical Code (NFPA 70) and
local codes & ordinances.
•
Voltage Rating – 115V / 60 Hz / 15 or 20 Amps
•
Amps @ 115 Volts = 5 Amps
•
Always consult local and national electric & plumbing codes.
•
Minimum opening of 66" H x 33" W x 25-1/4" D required for single-unit
"Built-In Look" installation; 66" W required for double-unit installation.
(66" H to be measured from finished floor to underside of soffit or
overhead cabinet.)
Minimum 25-1/4" depth requires recessed electrical outlet and
•
copper water line.
•
Remove all wall / floor molding prior to built-in installation.
•
When installing refrigerator adjacent to wall, cabinet or other
appliance that extends beyond front edge of unit, 20" minimum
clearance recommended to allow for optimum 140° door swing,
providing complete crisper access and removal. (Absolute 4"
minimum clearance will ONLY allow for 90° door swing which
will provide limited crisper access with restricted removal.)
FRIGIDAIRE®
USA
250 Bobby Jones Expressway
•
•
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
•
•
FPUH17D7K 05/09
Martinez, GA 30907
1-800-FRIGIDAIRE
•
1-800-265-8352
•
© 2009 Electrolux Home Products, Inc.
Note: Optional Trim Kits available for Built-In
All Freezer. For specifications, refer to Trim Kits
Installation page on web.
•
Optional Ice Maker Kit (PN # IM501) available for installation.
Water line for ice maker can enter opening through floor or rear wall.
•
Copper tubing recommended between cold water line and water
connection location. Water line tubing recommended is 48" minimum
length by 1/4" diameter. Installation of easily accessible shutoff valve
in water line required.
•
To allow for ease of moving out side-by-side units after installation,
84" minimum length of coiled copper tubing recommended.
•
Freezer must be placed on level surface of hard material, same height
as flooring. Surface must support approximately 800 lbs. when fully
loaded. Unit equipped with 4-point leveling.
•
If optional Single or Double Trim Kit is to be used, different cutout
dimensions are required. (Refer to cutout dimensions on this page
and to Trim Kits Installation Specifications page on web.)
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Optional Accessories
•
Single Trim Kit – (PN # ALLFRZKIT).
•
Double Trim Kit – (PN # DUOTRIMKIT).
•
Ice Maker Kit – (PN # IM501).