1.
@%:v®n"ed
ns_J _@w"s o_"t_'
Fit vent system over transition piece.
A
B
A. Transition
B. 3.5 x 6.5 mm screw
2. Seal connection with clamps.
Electrical Shock Hazard
Disconnect
power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical
shock.
1. Disconnect
power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box cover and install a
UL-listed or CSA approved V2"strain relief.
4. Run 3 wires, black, white and green (14AWG), in 1/2"conduit
from service panel to terminal box.
D
E
F
A. UL listed or CSA approved strain relief
B. 1/_ ,,conduit
C. Terminal box
D. Black wires
E. Green (or bare) wire connected
to yellow-green
wire
F. White wires
5. Use UL listed wire connectors
and connect black wires
together.
6. Use UL listed wire connectors
and connect white wires
together.
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal
box.
Failure to do so can result in death or electrical
shock.
7. Connect ground wire to green and yellow ground wire in
terminal box using UL listed wire connectors.
8. Replace terminal box cover.
9. Check all light bulbs to make sure they are secure in their
sockets.
10. Reconnect power.
1.
Install vent cover.
•
When using both upper and lower vent covers, push
lower cover down onto hood and lift upper cover to
ceiling and install with two 2.9 x 6.5 mm screws.
NOTE: Upper vent cover may be reversed to hide slots.
D
....
C
Oo_-
....................
A
A. Upper vent cover
B. Lower vent cover
C. 2.9 x 6.5 mm screws
D. Bracket
For reduced ceiling height installations, using the upper or
lower vent cover, push cover down onto hood and snap
vent into place around vent cover bracket.