Make Electrical Connection
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Remove terminal box cover using a T10 Torx
(or the T10 adapter provided) to remove screws.
3. Remove the knockout in the terminal box and install
a UL listed or CSA approved ¹⁄₂" strain relief.
A. Terminal box
B. Knockout
C. Terminal box cover
4. Run home power supply cable through strain relief
into terminal box.
G
A. Home power supply cable
B. UL listed or CSA approved strain relief
C. UL listed wire connectors
D. White wires
E. Black wires
F. Green (or bare) and yellow-green ground wires
G. Terminal box
10
®
drive
C
B
A
A
B
C
D
E
F
5. Use UL listed wire connectors and connect black
wires (E) together.
6. Use UL listed wire connectors and connect white
wires (D) together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
7. Connect green (or bare) ground wire from home power supply
to yellow-green ground wire (F) in terminal box using UL listed
wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Check that all light bulbs are secure in their sockets.
11. Reconnect power.
Install Vent Covers
When using both upper and lower vent covers, push lower
cover down onto hood and lift upper cover to ceiling. Install
with (2) 4.2 x 8 mm T20
®
screws using a T20
T20
®
adapter provided) to tighten.
NOTE: For vented installations, upper vent cover may
be reversed to hide slots.
C
D
A. Upper vent cover
B. Lower vent cover
C. 4.2 x 8 mm screws
D. Bracket
®
Torx
®
drive (or
A
B