MASTER ONE – TECHNICAL DOCUMENTATION
Page 10
On the PRIVATE ONE charging station, the CAN bus cable is connected onto the terminals 17 (CAN+)
and 18 (CAN-):
This schema may vary according to the controlled P1 charging station.
There must be a
shielded
twisted pair cable (e.g. As DATA Dca-flex C 2x2x0.75 shielded) are used. The
cable must not be longer than 2 cm. The shield and the cables that are not used for the CAN, must be
connected to the ground terminal or GND. It is forbidden to use the free cables for other functions.