IKEA LAGAN Manual - Page 18

Browse online or download pdf Manual for Ventilation Hood IKEA LAGAN. IKEA LAGAN 24 pages. Examples of the load of the basket
Also for IKEA LAGAN: Assembly Instructions Manual (8 pages), User Manual (20 pages), User Manual (16 pages), User Manual (20 pages), Instructions Manual (48 pages), User Manual (16 pages), User Manual (24 pages), Manual (28 pages), Instruction Manual (24 pages), User Manual (24 pages), Manual (24 pages), Manual (4 pages), User Manual (12 pages), Manual (24 pages), Assembly Instructions Manual (20 pages), Installation Manual (20 pages), Manual (28 pages), Manual (32 pages), Manual (44 pages), Manual (16 pages), Manual (16 pages), Manual (24 pages), Manual (28 pages), Manual (28 pages), User Manual (28 pages), Manual (40 pages), Manual (48 pages), Use & Care Manual (25 pages), Manual (44 pages), Manual (40 pages), Manual (28 pages), Manual (28 pages), User Manual (24 pages), Manual (48 pages), User Manual (16 pages), Installation Instructions Manual (18 pages), Manual (48 pages), Quick Start Manual (4 pages), Installation Instructions Manual (16 pages), Manual (28 pages), Manual (28 pages), Manual (44 pages), Manual (48 pages), Manual (16 pages), Manual (32 pages), Manual (24 pages), Manual (25 pages), Manual (18 pages), User Manual (28 pages), Manual (44 pages), Manual (32 pages), Manual (18 pages), Manual (48 pages), Manual (29 pages), Manual (29 pages), Manual (34 pages), Installation Instructions Manual (42 pages)

IKEA LAGAN Manual
ENGLISH
Gas setting conversion
You can use this model with
natural gas. However, you can
convert it for use with other
gases, providing the correct
injectors.
For more information on injector
replacement, refer to the Technical data
chapter.
Warning! Conversion or
replacement can only be
performed by a authorised
technician.
To replace injectors:
1. Remove pan support.
2. Remove burner cap and crown.
3. Using a socket spanner 7, unscrew and
remove the injectors, and replace them
with the ones required for the type of
gas in use.
4. Reassemble the parts, following the
same procedure backwards.
Place the label with relevant
information for new type of gas
close to the supply pipe before
sealing the appliance. If the
appliance is already sealed please
stick it directly on the user
manual booklet, after Technical
data chapter, and close to the
rating plate drawing.
You can find this label in package
supplied with appliance.
If the feeding gas pressure is
different or variable from the
required one, you must install an
appropriate pressure adjuster,
which is not supplied with the
product. If needed, it must be
ordered separately from the local
After Sales Service Provider, refer
to the Service chapter. The
pressure adjuster must be fitted
on gas supply pipe, in compliance
with the rules of the force.
The rating plate is located below the surface
of the casing.
Adjusting flame level
When you install the hob, it is necessary to
check the minimum flame setting:
1. Turn the gas tap to the maximum
position and ignite.
2. Set the gas tap to the minimum flame
position and turn the control knob from
minimum to maximum several times. If
the flame is unstable or extinguished,
follow the procedure further.
3. Re-ignite the burner and set to
minimum.
4. Remove the control knob .
5. To adjust, use a thin bladed screwdriver
and turn the adjustment screw until the
flame is steady and does not extinguish
when the knob is turned from minimum
to maximum, and vice versa (see
following picture).
6. Repeat this procedure for all burners.
7. Reassemble the knobs.
18