Replacing the Light Bulb
Turn off the range hood and allow the light bulb to cool.
1. Disconnect power.
2. Squeeze the plastic lens cover and remove it from the hood.
A. Light bulb socket
B. Lens cover
14
B
A
WIRING DIAGRAM
Motor Switch
Off - On
NOTE: Speed 1
not used
C25
Motor Characteristics
Power Supply
120 VAC
Frequency
60 Hz
Amperage
1.2 ±10% A
Wattage Rating
73 ±10% Watts
Motor Resistance
White - Red
17.1 ±10% Ohms
White - Black
13.6 ±10% Ohms
3. Screw light bulb into socket.
4. Replace lens cover by squeezing cover and inserting tabs
into slots.
5. Reconnect power.
If new light does not operate, make sure the lamp is inserted
correctly before calling service.
Lamp Switch
Off - Low - High
1
2
Lamp Switch
1 - 2
1 - 3 Low
L
3
1 - L High
Rectifier
Diode
Ground
Screw
SE114A
N
L
GND
Operation
Off