IKEA LUFTIG Installation Instructions - Page 3

Browse online or download pdf Installation Instructions for Ventilation Hood IKEA LUFTIG. IKEA LUFTIG 4 pages. Exhaust hood
Also for IKEA LUFTIG: User Manual (12 pages), Instruction Manual (28 pages), User Manual (12 pages), Installation Instructions And Use & Care Manual (44 pages), Manual (16 pages), Installation Manual (24 pages), Instruction Manual (40 pages), Manual (16 pages), User Manual (28 pages), Assembly (11 pages), Manual (24 pages)

IKEA LUFTIG Installation Instructions
BEFORE USE
Keep the packaging material out of reach of children.
*
Please read these instructions carefully and keep them for future reference.
*
Peel off protective film before using the product for safety. Fig. 3.
*
Use after removing of PVC film surface must be cleaned with cotton or cloth.
*
For Any Further Queries Please Call at our Toll Free no.
*
PRECAUTIONS
Ensure that the mains voltage corresponds with the recommended voltage of the chimney.
*
Connect the chimney to the electric supply with proper earthing.
*
When installed, the minimum gap between the Chimney and the hob must be 700mm for Gas hob &
*
500mm for Electric hob as Fig.4
Never leave frying pans unattended during use, as overheated oil may catch fire.
*
In the Ducting mode, the chimney duct must not be connected to an outlet that is used for exhausting fumes
*
from other appliances like central heating flue.
Before carrying out any maintenance, unplug the chimney from electric supply.
*
*
Never use high naked flame under the chimney when it is in operation.
*
When using a gas hob underneath the chimney, never leave the burner of the hob uncovered while the
chimney is in use or when the pans have been removed. Switch-off the burner after usage, never leave the
burner "ON", when unattended / not in use.
Always ensure that the appliance is used in accordance with the manufacturer's instruction.
*
INSTALLATION
The Chimney can be installed as Extraction Mode (Ducting) and Re-circulating Mode (Recycling). All Chimneys perform more efficiently in
*
the Ducting Mode.
The installation must be done by an authorised service representative, with thorough knowledge of the parameters concerning installation of
*
chimney.
Ensure that the installation is carried out as per enclosed general installation guidelines mentioned in the booklet.
*
Use recommended size 150 mm for the outlet duct pipe ( minimum is 120 mm). A duct pipe with a smaller cross-sectional area damages the unit and
*
also invalidates the warranty. Best suited flexible ducting pipes are available with service centers at an additional cost.
Wall marking:
• Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the
centre of the area in which the hood will be installed.
• Place bracket 5 on the wall as shown about 1-2 mm from the ceiling or upper limit, aligning
the centre (notch) with the vertical reference line.
• Mark the wall at the centres of the holes in the bracket.
• Place bracket 5 on the wall as shown at X mm below the first bracket (X = height of the
upper chimney section supplied), aligning the centre (notch) with the vertical line.
• Mark the wall at the centres of the holes in the bracket.
• Place bracket
4
as shown 1 10 mm from the vertical reference line and 163 mm base of
the chimney till the hood body fixing bracket.
• Mark the centres of the holes in the bracket.
• Repeat this operation on the other side.
3
WARNING !
Peel off protective
film before using the
product for safety.
Fig. 3
500 / 700 mm
Fig. 4
5
4
Fig. 5
AA-2037583-3