Decora LEVITON ODS0D-IDW Installation Instructions

Browse online or download pdf Installation Instructions for Accessories Decora LEVITON ODS0D-IDW. Decora LEVITON ODS0D-IDW 2 pages. Designer wall switch occupancy sensor

• Leviton's Decora
C O L L E C T I O N B Y L E V I T O N
• Low Profile, tamper-resistant lens
Designer Wall Switch
Occupancy Sensor
Leviton Cat. No. ODSØD-IDx, Designer Wall Switch Occupancy Sensor, is designed to detect motion from a heat-emitting source (such as a
Single Pole (One Location)
person entering a room) within its field-of-view (monitored space) and automatically switch lights ON and OFF.
or Multi-Location
Cat. No. ODSØD-IDx is an Occupancy Sensor that is designed to control two separate lighting circuits from a single unit. This allows the
user to replace two standard switches with a single unit that will also provide the convenience and energy savings of an occupancy sensor.
Rated: 120/277V, 60Hz
The Sensor is programmed to activate the lights for two main lighting applications. For reference purposes, these two types of operation are
designated as Classroom Mode and Conference Room Mode. During installation, the Sensor can easily be programmed to operate in either
Cat. No. ODSØD-IDx
one of these two modes.
Classroom Mode:
Incandescent
With the sunlight from the windows, artificial lights are not always needed. The main feature in this mode is that the Sensor will turn on the
800W @ 120V Primary
Primary Load when it first detects motion. Two seconds after the Primary Load turns ON, the Sensor will take a measurement of the ambient
800W @ 120V Secondary
light in the room. The Sensor will then either turn the Secondary Load ON or leave it OFF depending on the level of the light in the room.
This level is user set through the use of the Ambient Light Override feature (refer to Adapting Ambient Light Override section and
Fluorescent
Figure 2A).
1200VA @ 120V Primary
Conference Room Mode (Default Setting):
In conference rooms or similar rooms, there may be little or no natural light. When in the Conference Room Mode, the operation focuses on
800VA @ 120V Secondary
providing illumination for the task being performed.
Fluorescent
In this mode, the Sensor will take a measurement of the ambient light in the room when it first detects motion. If there is enough light in the
room, the Sensor will leave the lights OFF. If there is not enough light in the room, the Sensor will turn the lights ON to the last state that
2700VA @ 277V Primary
they were in (i.e. Primary Load ON and Secondary Load OFF). However, the one exception is if the last state was with both loads OFF and
1200VA @ 277V Secondary
there is not enough ambient light in the room. In this condition, the Sensor will turn the Primary Load ON.
Supplemental
The main feature of this Occupancy Sensor is its versatility to be used for most lighting requirements. For example, the Primary Load may be the
lights over a conference table. These lights may be all the illumination that is needed. Therefore, the Sensor will keep the Secondary Load OFF.
1/4hp @ 120V Primary
However, if it becomes necessary to use the perimeter of the room, the sensor's push- buttons can be used to turn the secondary load ON. Once
1/4hp @ 120V Secondary
these lights are no longer required, the Secondary Load can be turned OFF and will remain OFF.
Note that the Sensor will time out and turn the lights OFF after no motion is detected, regardless of mode of operation.
No Minimum Load Required
Cat. No. ODSØD-IDx is UL listed, CSA certified and conforms to California Title 24 requirements.
Compatible with electronic and magnetic ballasts,
electronic and magnetic low-voltage ballasts,
The Occupancy Sensor senses motion within its coverage area of 2400 sq. ft (223.3 m
incandescent lamps, and fans.
is a self-contained device which provides sensing and light control. The Occupancy Sensor will turn the lights ON when motion is initially
Installation Instructions
detected, and keep the lights ON for as long as motion is detected.
The Occupancy Sensor uses a small semiconductor heat detector that resides behind a multi-zone optical lens. This Fresnel lens
establishes dozens of zones of detection. The sensor is sensitive to the heat emitted by the human body. In order to trigger the Sensor, the
DI-000-ODS0D-00A
source of heat must move from one zone of detection to another. The device is most effective in sensing motion across its field-of-view, and
less effective sensing motion towards or away from its field-of-view (refer to figures 1 and 1A). Keep this in mind when selecting the
installation location (refer to figures 1 and 1A).
Note that occupancy sensors respond to rapid changes in temperature, so care should be taken not to mount the device near a climate
LIMITED FIVE YEAR WARRANTY AND EXCLUSIONS
control source (i.e. radiators, air exchanges, and air conditioners). Hot or cold drafts will look like body motion to the device and will trigger it
Leviton warrants to the original consumer purchaser and not
if the unit is mounted too close. It is recommended to mount the Occupancy Sensor at least 6 ft. away from then climate control
for the benefit of anyone else that this product at the time of its
source. The device can be mounted in a single gang wall box.
sale by Leviton is free of defects in materials and workmanship
In addition, it is also recommended NOT to mount the Occupancy Sensor directly under a large light source. Large wattage bulbs (greater
under normal and proper use for five years from the purchase
than 100W incandescent) give off a lot of heat and switching the bulb causes a temperature change that can be detected by the device.
date. Leviton's only obligation is to correct such defects by
Mount the Occupancy Sensor at least 6 ft. away from large bulbs. If it necessary to mount the device closer, lower the wattage of the bulb
repair or replacement, at its option, if within such five year
directly overhead.
period the product is returned prepaid, with proof of purchase
date, and a description of the problem to Leviton
Manufacturing Co., Inc., Att: Quality Assurance
Department, 59-25 Little Neck Parkway, Little Neck, New
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device must not cause
York 11362-2591 (In Canada send to Leviton Mfg. of Canada
harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Ltd., 165 Hymus Blvd., Point Claire, (Quebec), Canada, H9R
1E9). This warranty excludes and there is disclaimed liability
for labor for removal of this product or reinstallation. This
WARNING:
warranty is void if this product is installed improperly or in an
WARNING:
improper environment, overloaded, misused, opened, abused,
WARNING:
or altered in any manner, or is not used under normal operating
ELECTRIC SHOCK, PERSONAL INJURY OR DEATH. CHECK YOUR LOAD RATINGS TO DETERMINE SUITABILITY FOR YOUR
conditions or not in accordance with any labels or instructions.
There are no other or implied warranties of any kind, including
APPLICATION.
merchantability and fitness for a particular purpose, but if any
WARNING:
implied warranty is required by the applicable jurisdiction, the
OTHER CAUTIONS AND NOTES:
duration of any such implied warranty, including merchantability
1. DISCONNECT POWER WHEN SERVICING FIXTURE OR CHANGING BULBS.
and fitness for a particular purpose, is limited to five years.
2. USE THIS DEVICE WITH COPPER OR COPPER CLAD WIRE ONLY. WITH ALUMINUM WIRE, USE DEVICES MARKED CO/ALR OR
Leviton is not liable for incidental, indirect, special, or
consequential damages, including without limitation, damage
3. DO NOT TOUCH THE SURFACE OF THE LENS. CLEAN OUTER SURFACE WITH A DAMP CLOTH ONLY.
to, or loss of use of, any equipment, lost sales or profits or
delay or failure to perform this warranty obligation. The
4. THE CAT. NO. ODSØD-IDx OCCUPANCY SENSOR IS INTENDED TO REPLACE A STANDARD LIGHT SWITCH.
remedies provided herein are the exclusive remedies under
TO INSTALL:
this warranty, whether based on contract, tort or otherwise.
NOTE: Cat. No. ODSØD-IDx requires a ground connection in order to operate. Use the ground wire in the electrical box for ground
connection. If there is no ground wire, make sure the electrical box is grounded and attach the ground wire to the box with a screw.
For Technical Assistance Call:
1.
1-800-824-3005 (U.S.A. Only)
1 800 405-5320 (Canada Only)
2. Connect wires per appropriate WIRING DIAGRAM as follows: BLACK wire to LINE (phase 1). One RED wire to Line (phase 2). If only one
www.leviton.com
DI-000-ODS0D-00A
FEATURES
®
style design
• Switches 2 separate lighting loads
• Adapting time and ambient light
INTRODUCTION
DESCRIPTION
FCC COMPLIANCE STATEMENT
INSTALLATION INSTRUCTIONS
TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS.
IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A QUALIFIED ELECTRICIAN.
CONTROLLING A LOAD IN EXCESS OF THE SPECIFIED RATINGS WILL DAMAGE THE UNIT AND POSE RISK OF FIRE,
DO NOT INSTALL THIS UNIT TO CONTROL A RECEPTACLE.
CU/AL ONLY.
WARNING:
TO AVOID FIRE, SHOCK, OR DEATH: TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER
IS OFF BEFORE WIRING.
phase is used, connect BLACK and RED wires together. The remaining RED wire to BANK 2. BLUE wire to LOAD (or BANK 1). GREEN wire
to GROUND. Twist strands of each lead tightly and, with circuit conductors, push firmly into the appropriate wire connector. Screw
connector on clockwise making sure that no bare wire shows below the connector. Secure each wire connector with electrical tape.
NOTE: THE BLUE WIRE IS THE PRIMARY LOAD CONNECTION (HIGHER RATED).
3. Ensure that the Service Switch (refer to Figure 2) is in the AUTO position (middle position). Cat. No. ODSØD-IDx must begin operation
in the AUTO mode.
4. Carefully position the wires into the wall box, then mount the Sensor Unit into the wall box.
5. Secure device using long mounting screws provided.
6. Restore power at circuit breaker or fuse.
NOTE: Cat. No. 0DSØD-IDx will beep once 5 seconds after power is applied. After approximately 25 seconds the lights will turn ON.
Both lights always turn ON 25 seconds after power is applied, no matter what mode it is in or what the settings are. Allow
approximately 1 minute for charge-up. If the lights turn ON and the LED blinks when a hand is waved in front of the lens, then the
Sensor was installed properly. If the operation is different, refer to the Troubleshooting Section.
Cat. No. 0DSØD-IDx is factory preset to work without any adjustments. If you desire to change the factory settings, refer to the Settings
section below.
7. Attach the Control Panel cover, and a Decora
will turn OFF after the selected time-out expires.
Factory Settings: The Sensor is shipped from the factory to work in almost all situations without any added adjustments. The factory
settings are: Blinders open, Base time-out 10 minutes, Lights always turn ON regardless of existing light levels, and Maximum range. The
default operation is the Conference Room Mode.
Blinders: The blinders are two independent shutters that can narrow the field-of-view from a maximum of 180° down to 32°. The blinders
are operated by moving the blinder levers towards or away from the center of the Sensor. The blinder levers can be found above the control
dials in the control panel (refer to figure 2A).
Time-Outs: The Sensor has three types of Time-Outs: Walk-through, Base Time, and Adapting.
Walk-through Time-Out: The value of this time-out is preset to 2.5 minutes. It is used by the Sensor as a starting point in adjusting the
other types of time-outs.
Base Time-Out: The value of this time-out is user selected through the use of the Time Control Setting.
Adapting Time-Out: When activated, the value of this time-out is changed by the Sensor based on room occupancy and lighting conditions.
Walk-Through: The walk-through feature is useful when a room is momentarily occupied. With this feature, the Sensor will turn the lights
OFF shortly after the person leaves the room.
The walk-through feature works in the following manner: When a person enters the room, the lights will turn ON. If the person leaves the
room before the default walk-through time-out of 2.5 minutes, the Sensor will turn the lights OFF. If the person stays in the room for longer
than 2.5 minutes, the Sensor will instead use the time-out per the Time Control Setting (refer to Time Control Setting in the following sections).
The walk-through feature may be user disabled (refer to Non-Adapting Mode in the following sections).
Audio Warning: The Sensor is equipped with a beeper to give the user feedback of unit operation. During normal operation, the Sensor will
issue three short beeps 20 seconds before the time-out is over to alert the user that the lights are going to turn OFF. The occupant must
2
) maximum and controls the connected lighting. This
move in order for the lights to remain ON. The Sensor issues two short beeps to let the occupant know that motion was detected and that
the lights will stay ON.
Adapting Time Delay: The Sensor has built in adapting intelligence that changes the adapting time-out duration in response to the
occupancy conditions of the room it is installed in.
If the Sensor detects "large" motions (as a person walking by), it will NOT change the time-out duration. If the Sensor detects "small",
infrequent motion (as a person sitting down and writing), it will INCREASE the Adapting Time-Out duration. If the Sensor detects "small",
frequent motion (as in several persons in a room during a meeting), it will DECREASE the Time-Out duration only if it was NEVER increased
(this is because the built-in intelligence will always proceed in the direction of "increasing" adapting time-out once it has increased it for any
of the occupancy conditions sensed).
If the room is occupied for longer than 2.5 minutes, the Sensor will enter the Occupied Mode with the Time-Out duration specified by the
Time Control Setting. This Time-Out is used as the starting point for adapting. After a few days, the Time-Out value will adapt to the "best"
value based on the occupancy conditions detected in the room.
If the Sensor detects motion immediately after the audio warning beep, it will determine that the existing Time-Out value is too short. The
Sensor will thus increase the Time-Out value by 1.5 times the existing value.
If the Sensor detects motion within 45 seconds after the lights turn OFF, it will turn the lights ON and increase the Time-Out value by 1.5
times the existing value.
The adapted Time-out may be reset to the base value by rotating the Time Control to a new time selection value (refer figure 2A).
Time Control Setting: The base Time-Out value is selected by rotating the
Time Control dial. There are four (4) values from which to choose. Each
mark around the dial corresponds to a different value as indicated below
(refer to figure 2A). The Sensor will beep once to indicate that a new time
value has been selected.
NOTE: All time durations is approximate within ±10 seconds.
Adapting Ambient Light Override: The Ambient Light Override is used to
keep the lights OFF if there is already enough natural light in the room. For proper operation, the Ambient Light Override adjustment must be
performed when there is enough natural light (refer to the Settings section). If the adjustment is made when there is less natural light, the
lights may not turn ON even though they are needed. This will require manual activation of the push-buttons to turn the lights ON.
If the Ambient Light Override Adjustment is not performed properly, the Adapting feature will adjust this setting. The Sensor will use the light
level prior to turning the lights ON as the new Ambient Light value and increase it slightly so that next time the same conditions are present,
it will turn the lights ON. This adapting feature may take a few cycles prior to adjusting to the proper light level.
If the Ambient Light Override is not performed, the adapting feature will not be utilized (refer to Ambient Light Dial in the following section).
NOTE: The ambient light level in the center of a room will be different then the level at the wall where the switch is located.
NOTE: The adapting light level only affects the Secondary Load when in the Classroom Mode and affects both loads in the Conference
Room Mode.
Ambient Light Dial: The ambient light setting is adjusted with the Ambient Light dial (refer to figure 2A). Turning the Light Dial fully
counter-clockwise (CCW), sets the Sensor to manual ON mode (lights always turn ON) (see following section). All other settings will cause
the lights to turn ON only when the light level is less than the setting.
To prevent false low light levels from the user standing in front of the device during adjustment, the Sensor remembers the Ambient Light
level from 1 minute ago.
There are two ways the Adapted Ambient Light level can be reset to the level set by the dial: (1) By rotating the Light Dial, the adapted value
will be replaced by the new value corresponding to the new position of the dial. (2) By pressing and holding either button for 3 seconds; the
Sensor will beep once and reset the Adapted Light Level value to the dial setting.
NOTE: When the setting is at the minimum CCW level, the lights will stay OFF when the room is dim. When the setting is at the maximum
level clockwise (CW), the lights will turn ON when the room is bright.
®
Wallplate (not included). INSTALLATION IS COMPLETE. Leave the room and the lights
FEATURES
Face Marking
Value of Time
(/) Slash Mark
30 second test mode, NO walk-through
1
5 minutes base time-out
2
10 minutes base time-out
3
20 minutes base time-out