Avantco 178MC49HC User Manual - Page 6
Browse online or download pdf User Manual for Kitchen Appliances Avantco 178MC49HC. Avantco 178MC49HC 9 pages. School milk cooler
Also for Avantco 178MC49HC: User Manual (9 pages)
Adjusting the Temperature
Your new milk cooler is already factory-set to run at optimum temperatures for food safety and should
require no adjustments.
Refrigerators are set to cycle between a minimum temperature of 33 degrees Fahrenheit and a maximum
temperature of 40 degrees Fahrenheit.
Adjusting the temperature changes the minimum temperature your unit will run at. Your unit will not run
constantly at this setting. To change it, follow these instructions:
DIGITAL CONTROL UNITS
•
Hold "SET" for 1 second The display will flash the current minimum temperature.
•
Use the arrow buttons to adjust the minimum temperature you want it to run at.
•
Press "SET" again to save your settings.
Always remember to calculate the differential if you change the minimum temperature setting. The cabinet
temperature will fluctuate up to +7 degrees over your set minimum temperature as the compressor runs
and shuts off. Setting the temperature too high will result in unsafe maximum temperatures and possible
health code violations.
RUNNING A MANUAL DEFROST CYCLE
Units are pre-programmed to run automatic defrost cycles at preset intervals. However, if you would like to
run a manual defrost cycle at any time, please follow the steps below:
1. Press the defrost button (snowflake symbol and down arrow) for approximately 3 seconds.
2. Repeat to stop the defrost cycle.
NOTE: Ensure a drain is accesible for the unit to catch water from defrost cycle.
Safety / Warning
Please pay close attention to the safety notices in this section. Disregarding these notices may lead to serious
injury and/or damage to the unit.
ATTENTION
•
To minimize shock and fire hazards, be sure not to overload outlet. Please designate one outlet for your unit.
•
Do not use extension cords.
•
Do not put your hands under the unit while it is being moved.
•
When the unit is not in use for a long period of time, please unplug the unit from the outlet.
•
After unplugging the unit, wait at least 10 minutes before plugging it back in. Failure to do so could cause
damage to the compressor.
UNPLUG CORD
•
To minimize shock and fire hazards, please do not plug or unplug the cord with wet hands.
•
During maintenance and cleaning, please unplug the unit.
www.AvantcoRefrigeration.com
6
User Manual
Commercial School Milk Coolers