GAPOSA QC400 Manual - Page 14
Browse online or download pdf Manual for Engine GAPOSA QC400. GAPOSA QC400 16 pages. Automatic control unit for three/single-phase motors with digital or mechanical limits
10 SPECIAL TECHNICAL INFORMATION
Go Func normal
: Go function input terminal X5-11,12. (DIP7 OFF)
Go function, when photo safety is connected to controller:
When Door is not open
When door is open
When door is running down
When door is running up
Go function, when no photo safety is connected to controller:
When Door is not open
When door is open
When door is running down
When door is running up
Go Func special
: Go function input terminal X5-11,12. (DIP7 ON)
Go function, when photo safety is connected to controller:
When Door is not open or closed > the door will do opposite of last.
When door is open
When door is running down
When door is running up
Go function, when no photo safety is connected to controller:
The "go function special" is not active when no photo is connected. (safety)
Photo disabling before the door reaches the floor level
If you want to disable the photo safety function a little distance before close limit:
1. Move the door to the desired disabling point -
2. Activate the STOP button and then also the OPEN + CLOSE buttons for 5 sec. ( 3-double push)
3. Confirm LED will flash 1 sec.
Check that that the disabling point is correct.
14
> the door will open.
> the door will start closing.
> the door will open.
> no change.
> the door will open.
> no closing (for safety reason because no photo)
> the door will open.
> no change.
> the door will start closing.
> the door will stop and next push opening.
> the door will stop and next push closing