Avantco 224BHAC51 User Manual - Page 5

Browse online or download pdf User Manual for Merchandiser Avantco 224BHAC51. Avantco 224BHAC51 9 pages.

Avantco 224BHAC51 User Manual
User Manual
Refrigerator Control
set
Running a Manual Defrost Cycle
This unit is pre-programmed to run automatic defrost cycles at preset intervals. However, if you
would like to run a manual defrost cycle at any time, please follow the steps below:
Refrigerators: Press the defrost button (snowflake symbol and down arrow) for approximately 3
seconds. Repeat to stop the defrost cycle.

Defrost System

Refrigerator coils are kept below the freezing point (32 degrees Fahrenheit). During compressor
down-time, the evaporator fan continues to circulate air through the evaporator coil. This air
circulation raises the coil temperature above the freezing point, melting any accumulated frost.
Run-off water is drained into the evaporator pan and evaporated. Automatic defrost timers
automatically initiate at pre-set intervals and for a pre-determined duration.
Operation/Maintenance
NOTE: We strongly recommend that any servicing be performed by an authorized service technician.

Loading Product

• Do not block the air duct / fan at the top of the unit. Maintain a minimum of 4" of clearance
between products and the fan at all times. Do not block return air flow in the front of the unit.
• Ensure all shelves are sitting level and properly secured before loading products.
• Do not store flammable and explosive gas or liquids inside the unit.
Cleaning the Condensor Coil
• For efficient operation, keep the condenser surface free of dust, dirt, and lint.
- 5 -