FRIGOGLASS Flex 20 HC User Manual - Page 13

Browse online or download pdf User Manual for Merchandiser FRIGOGLASS Flex 20 HC. FRIGOGLASS Flex 20 HC 15 pages.

FOR AUTHORIZED SERVICE PERSONNEL ONLY
It is mandatory that the Customer performs the following operations during the Maintenance of an ICM
once or twice a year, using a vacuum cleaner:
Cleaning of the condenser
Cleaning of the dust filters (if applicable).
If the ICM is placed in an environment where dust is accumulated on the condenser, then the
condenser has to be cleaned more often.
Additionally, it is recommended that the following operations are carried out during preventive
maintenance:
1. Mechanical System:
Check that the equipment is correctly positioned and leveled.
Check that the front and back grid are fixed in place.
Check the self-closing system of the door.
Check that the fan support and fan grid are fixed in place.
Check the draining system and unclog if necessary.
2. Electrical System:
Check the power cable (replace if needed).
Check the illumination system.
Check the electrical connections.
Check that the electrical box cover of the thermostat or the electronic controller is properly
installed.
Check that components that might have been replaced during servicing are original.
HANDLING & TRANSPORTATION GUIDELINES
The merchandiser should always be transported:
in upright position (unless otherwise authorized by the supplier)
with the doors closed
in its original packaging or similar one.
Cooler temperature during storage or transportation should not be
o
below -20
C or above +60

PREVENTIVE MAINTENANCE GUIDELINES

PRIOR TO ANY CLEANING OR MAINTENANCE PROCEDURE (INSIDE
OR OUTSIDE THE DEVICE), UNPLUG THE ICM! REMOVE THE PLUG
AND MAKE SURE THAT THE OPERATOR CAN CHECK FROM ANY OF
THE POINTS WHICH HE HAS ACCESS THAT THE CABLE IS
UNPLUGGED.
APPENDIX A
o
C.
APPENDIX B
ENG
13