Shelf Installation

5.1
Mount the ECS directly onto the equipment
rack. Use the 23" rack adapter brackets if mounting to
a 23" equipment rack (Figure 3). If using a rack which
is threaded for 12-24 screws, the threaded clips are not
required and may be discarded. If the rack is threaded
for screws other than 12-24 screws, use the screws
supplied with the rack.
5.2
Determine the appropriate mounting position
for the unit and secure to frame using the proper
hardware. Ensure the unit is pushed back as far as the
sliding brackets will allow.
6.

Connector Access

In some applications, the ECS must be extended
forward to provide access to the input/output adapters.
This is accomplished by gripping the jumper trough on
each side and firmly pulling the unit forward.
NOTE: Take care to avoid pulling or bending jumpers
when you pull the housing out to access connectors.
7.

Jumper Routing

To ensure minimum bend radius, jumpers from the
outer four (4) I/O ports must be routed to the opposite
side of the unit (Figure 4). All other jumpers can be
routed in either direction.
SRP-009-222
KPA-2551
Attach for 23-in.
Rack Application
Figure 3
8.

Coupler Cassette Installation

Coupler
Cassettes
Knurled Nut
8.1
Corning Cable Systems recommends that the
ECS be ordered fully configured before installing into a
rack. This keeps jumpers and internal fibers from being
disturbed.
8.2
If the coupler circuit must change, coupler
cassettes can be removed from and added to the unit by
the following (refer to Figure 5):
• Disconnect jumpers and remove them from external
routing guides to avoid damage when the unit is
removed from the rack.
• Remove the mounting screws and carefully slide the
unit out of the rack.
• Remove the top cover by removing the screws on
top of the unit.
• Add or remove the proper coupler cassette by
removing the knurled nut from the threaded stud.
Route and connect or remove and disconnect the
required pigtails within the unit.
• Reverse the previous steps to reassemble the unit.