CORNING NI-3012 Customer Instructions - Page 3

Browse online or download pdf Customer Instructions for Network Hardware CORNING NI-3012. CORNING NI-3012 4 pages. Network interface device

NI-3012 Network Interface Device — Telephone Company Instructions
The model NI-3012 Network Interface Device
(NID) (Figure 5) is designed to allow up to 12
telephone lines to be installed. It is equipped with
a Universal Line Module (ULM) and Universal
Station Protector (USP) which provide Telco/
customer termination, line protection, and
optional Telco electronics in one unit. The unit
may be upgraded by adding additional lines as
required.
6.
Installation
Step 1:
Remove existing protector and
enclosure from building, if installed.
Step 2:
Select desired mounting location.
Select appropriate mounting features
for secure mounting: external
mounting ears or vertical conduit
mounting.
7.
Service Hookup
Step 1:
Open telco cover using a pin and hex tool to turn the
two telco screws one-quarter turn. Remove the middle
rubber grommet and pierce with sharp object (Figure 6).
Feed drop wire and ground wire through grommet and
replace grommet.
NOTE: Drop wire terminals are Insulation Displacement Connectors (IDC); wires need not be stripped. The
terminals are identified with a "T" for tip and an "R" for ring.
Step 2:
Connect ground wire according to local code or practice using a #6 AWG ground wire.
Step 3:
Unscrew the stuffer on the USP until it is fully open
(Figure 7).
Step 4:
If using 22-24 AWG wire, it is necessary to use
the wire guide to facilitate proper wire insertion. If
wire guide has been misplaced, contact Corning
Customer Services to order replacement guides.
If using 18 AWG wire, remove the wire guide from the
protector holes. (It is recommended to retain the wire
guide in case it is needed later.)
a.
Untwist a pair of wires and straighten the ends before inserting into the protector. It is not
necessary to strip the insulation from the wires.
b.
Insert the wires into the holes in the USP, until the wires touch the back of the protector.
Step 5:
Screw the stuffer back down to make contact. Gently tug on all wires to check connection.
Step 6:
Close telco cover by pushing the telco screws back into position.
STANDARD RECOMMENDED PROCEDURE 203-297 | ISSUE 2 | MAy 2015 | PAGE 3 OF 4
Telco Screw
Customer Cover
KPA-2326
Telco Screw
TPA-5032
Wire Guide
Mounting Ear
Telco Cover
Mounting Ear
Figure 5
Figure 6
Stuffer
Wires
touch back
of protector.
Keep wires straight
while inserting.
KPA-2323
Figure 7