CORNING ONE GX Quick Installation Sheet - Page 6
Browse online or download pdf Quick Installation Sheet for Measuring Instruments CORNING ONE GX. CORNING ONE GX 14 pages. Higher power 40 w dual-band wcs/2.5 ghz tdd das remote
Also for CORNING ONE GX: General Information Manual (12 pages)
4.
(IF REQUIRED) FOR GX SUPPORTING THE
CELL BAND – INSTALL EXTERNAL FILTER
Note:
External filter (ordered separately – P/N: AK-GX-FILT-
850PS) is required if GX supporting the CELL band is
deployed along with units supporting the 800 MHz
band. The 850 CELL and 800 MHz service signals
must be conditioned and routed through two
separate RF paths. Refer to Figure 4.
Note the following:
• Either an OCH-4-WDM unit per GX or an OCH-8-WDM
(supporting two separate optical modules) is used.
• In installations with RIU, the services are conditioned via two
independent sectors (i.e., SectorA and SectorB) and routed
through dedicated optical modules in the OCH. One RIU-12
unit supports two sectors.
• In installations with RIU-4 – two RIU-4 units are required
(one for routing 850 CELL and one for 800 MHz).
It is recommended to perform this procedure before the
GX installation.
Figure 4. RF Signal Paths for GX Supporting S800 and GX with CELL 850 Deployed with HEU
Figure 5. RF Signal Paths for GX Supporting 800 MHz and GX with CELL 850 Deployed RIU-12
Corning Optical Communications
Quick Installation Sheet | CMA-581-AEN | Page 6