CORNING ONE HEU Quick Installation Sheet - Page 8
Browse online or download pdf Quick Installation Sheet for Measuring Instruments CORNING ONE HEU. CORNING ONE HEU 12 pages. Headend unit
10.
VERIFY NORMAL OPERATION
If RF source is operational, verify that the RIM (see Figure 7)
and HCM/ACM (see Figure 15) LEDs indicate normal operation:
Module
LED
RIMe
Protect
DL High
DL Low
RUN
PWR
HCM/ACM PWR
RUN
SYS
FAN
PSM
PWR
STATUS
Table 2. RIMe, HCM/ACM, and PSM LED Descriptions
Corning Optical Communications
Description
N/A
Off – DL RF input level in threshold range
Steady Red – DL RF input level is 3 dB above
maximum expected power
Off – DL RF input level in threshold range
Steady Red – DL RF input level is 15 dB below
maximum expected power
Blinking green – RIMe software has initialized
and is up and running
Off – Power off
Steady green – input power is within required
range
Steady green – power input detected by
HCM/ACM
Blinking green – HCM software up and running
Steady green – overall status of the managed
system is ok
Steady green – normal operation status for
all fans
On – power input detected
Off – no power
Figure 15. HCM/ACM LEDs
Figure 16. RIMe LEDs