CORNING OSE-ST-2 Manual - Page 3

Browse online or download pdf Manual for Enclosure CORNING OSE-ST-2. CORNING OSE-ST-2 8 pages. Splice trays

CORNING OSE-ST-2 Manual
5.
Routing Fiber
The recommended ribbon/fiber routing configurations are illustrated in Figure 2.
Loop the fiber twice around the inside perimeter of the tray (once for the OSE-ST-3-TQ and OSE-ST-9 trays).
Single- ber Splice Trays
OSE-ST-2:
36 Fusion splices using Crimp & Go®
splice protectors or RTV compound
OSE-ST-3:
6 Heat-shrink mass fusion splices
(12- ber ribbon, 72 total bers)
OSE-ST-3-TQ:
12 Heat-shrink mass fusion splices
(12- ber ribbon, 144 total bers)
IMPORTANT:
The fibers must enter/exit the tray at the same corner as shown in Figure 2. Strain-relieve the
buffer tubes appropriately as detailed in Sections 6-8. Fiber #1 enters the splice organizer from the
bottom and fiber #2 enters the splice organizer from the top.
6.
Securing Loose Tube Cable
Step 1:
Use a crimp tool (P/N M67-020) to secure buffer
tubes to the tray.
a. Adjust the stop screw on the crimp tool
until the jaws of the tool are equal to
the outer diameter of the buffer tube
(Figure 3).
b. Tighten the lock nut.
Ribbon Fiber Splice Trays
OSE-ST-1:
36 Heat-shrink fusion splices
OSE-ST-4:
36 Mechanical splices
3
2
36 splices 36 splices
36 splices
OSE-ST-9:
108 Heat-shrink fusion splices
(12- ber ribbon, 108 total bers)
Lock nut
Buffer tube
TPA-4948
Standard Recommended Procedure 001-285 | Issue 4 | February 2017 | Page 3 of 8
1
TPA-4946
Figure 2
Stop screw
Figure 3