Chapter 7 Circuit diagram
7-1. Brief principle diagram
Chapter 8 Trouble shooting
8-1. Normal phenomena
Problem
Freezer does not
operate or
Power-On Light
is not on
Freezer
starts/stops too
frequently
Freezer operates
too long
Livøvej 22 - 8800 Viborg - Tlf. 86 61 34 11 - [email protected] - www.vibocold.dk
Possible Causes
Temperature control in
OFF or Min or 0 position.
Freezer is unplugged.
The fuse is blown/circuit
breaker is tripped.
Door/lid left open.
Too frequent or too long to
door/lid openings.
Temperature control set
too cold.
Door/lid left open.
Total solutions in refrigeration and freezing
Issue 2014-03-13
Rev.
What To Do
Move the control to a temperature setting.
Push the plug completely into the outlet.
Replace fuse or reset the breaker
Check to see if package is holding door/lid
open.
Closed the door or reduce the times of
opening the door
See About the operation of your freezer
Check to see if package is holding door/lid
open.
Totalløsninger i køl og frys
Ref1102S001V0
14