Jandy Jandy Pro Series Installation And Operation Manual - Page 5

Browse online or download pdf Installation And Operation Manual for Water Filtration Systems Jandy Jandy Pro Series. Jandy Jandy Pro Series 20 pages. Single element cartridge pool & spa cs filters
Also for Jandy Jandy Pro Series: Owner's Manual (12 pages), Installation Manual (16 pages), Installation And Operation Manual (20 pages), Owner's Manual (20 pages), Manual (8 pages), Quick Start Manual (2 pages), Installation Instructions (2 pages), Installation And Operation Manual (16 pages), Installation And Operation Manual (16 pages), Installation And Operation Manual (16 pages)

Jandy Jandy Pro Series Installation And Operation Manual
Jandy Pro Series Levolor
II Electronic Water Leveler
®
Models K-2100

Section 2. System Description

Levolor II by Jandy Model K-2100 is a computer-
controlled fill device that detects low water conditions.
It can be used in any situation where a consistent liquid
level is desired and the low water condition can be
detected and acted upon. It is used to fill fountains and
to circulate water in cooling towers, ponds, reservoirs,
and storage tanks.
The K-2100 kit includes a sensor, remote sensor
housing, control box and solenoid valve. For details
about the materials in the kit and a list of additional
materials needed to install the K-2100, refer to
Section 3.1, Materials and Tools.
Sensor
The sensor has three (3) probes: one (1) short probe to
measure the minimum operating level of the water, one
(1) long probe to measure the low water cutoff level,
and one (1) long common probe. The long probes come
in 4", 18", and 30" lengths.
The sensor housing is a slip type housing that glues to a
1" coupling.
NOTE There is an optional threaded-type sensor for a
threaded fitting.
Depending on the model, the sensor comes with 50 to
500 feet of wire at the top and three (3) stainless steel
contacts at the bottom. The excess wire can be cut off
after the installation has been completed.
Control Box
The control box has five (5) LED lights:
- Power On
- Sensor
- Fill
- Low Water Sensor
- Low Water Cutoff
For details about the functions of the LED lights, refer
to Section 4.1, Controller Lights.
The control box is factory wired for 220 volt operation,
but can optionally be rewired for 110 volt operation. See
Section 3.3, Changing Wiring for 110 Volt Operation.
|
Installation and Operation Manual
Valve
The K-2100 requires one (1) 24VAC solenoid valve.
The Jandy-supplied valve (Part No. SOL100) has a
pressure rating that cannot exceed 125 PSI.
2.1
Electrical Specifications
Input: 110VAC, 50/60 HZ, 0.5 AMPS
220VAC, 50/60 HZ, 0.5 AMPS
Valve Output: 24VAC@ 1 AMP
Relay Output: 24VAC@ 1 AMP
Model K-2100 is factory wired for 220VAC
service. If the available electrical service is
110VAC, the power supply wiring must be
changed to operate on 110VAC, as shown in
Figures 3 and 4.
ENGLISH
CAUTION
Page 5