Introduction
Always consult your local Building Department regarding regulations,
codes or ordinances which apply to the installation of a vented wall
furnace.
Instructions to Installer
1. Installer must leave instruction manual with owner after
installation.
2. Installer must have owner fill out and mail warranty card supplied
with furnace.
3. Installer should show owner how to start and operate furnace and
thermostat.
Warning:
Any change to this furnace or its control can be dangerous. This
is a heating appliance and any panel, door or guard removed
for servicing an appliance must be replaced prior to operating
the appliance.
General Information
This series is design certified in accordance with American National
Standard / CSA Standard Z21.86 and CSA 2.32 by the Canadian Standards
Association, as a Fan Type Vented Wall Furnace and must be installed
according to these instructions.
Any alteration of the original design, installed other than as shown
in these instructions or use with a type of gas not shown on the
rating plate is the responsibility of the person and company making
the change.
Important
All correspondence should refer to complete Model No., Serial No. and
type of gas.
Notice: During initial firing of this unit, its paint will bake out and smoke
will occur. To prevent triggering of smoke alarms, ventilate the room in
which the unit is installed.
Installation on Rugs and Tile
If this appliance is installed directly on carpeting, tile or other combustible
material other than wood flooring the appliance shall be installed on a metal
or wood panel extending the full width and depth of the appliance.
DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANELS INSTALLED
• Due to high temperatures the appliance should be located out
of traffic and away from furniture and draperies.
• Children and adults should be alerted to the hazards of high
surface temperatures and should stay away to avoid burns or
clothing ignition.
• Young children should be carefully supervised when they are
in the same room as the appliance.
• Clothing or other flammable material should not be placed on
or near the appliance.
• Any safety screen or guard removed for servicing an appliance
must be replaced prior to operating the appliance.
• Keep burner and control compartment clean.
• Installation and repair should be done by a QUALIFIED SER-
VICE PERSON.
The appliance should be inspected before
use and at least annually by a qualified service person. More
frequent cleaning may be required due to excessive lint from
carpeting, bedding materials, etc. It is imperative that control
compartments, burners and circulating air passageways of the
appliance be kept clean.
• DO NOT put anything around the furnace that will obstruct
Page 2
The base referred to above does not mean the fire-proof base as used
on wood stoves. The protection is for rugs that are extremely thick and
light colored tile.
Installation in Residential Garages
Gas utilization equipment in residential garages shall be installed so
that all burners and burner ignition devices are located not less than 18"
(457mm) above the floor.
Such equipment shall be located, or protected, so it is not subject to
physical damage by a moving vehicle.
Specifications
Input BTU/HR (KW/H)
Height
Width
Depth
Gas Inlet Pipe
Vent Collar Type B Oval
CFM
Accessories
Register, side outlet, fixed register
Side outlet, 10" (254mm)
Rear outlet, 10" (254mm)
Vent enclosure, 24" (609mm)
Vent enclosure, 34" (86cm)
Vent enclosure, 46" (1168mm)
Oval-to-Round flue adapter kit 4" (102mm)
THIS IS A HEATING APPLIANCE
Model
40,000 (11.7)
72 1/2" (84.1mm)
14 1/8" (35.9mm)
10 3/8" (26.4mm)
1/2" (12.7mm)
maximum extension, fixed register
maximum extension, adjustable register
[for rooms up to 96 1/2" 2451mm) in height]
[for rooms up to 106 1/2" (2705mm) in height]
[for rooms up to 118 1/2" (3009mm) in height]
the flow of combustion and ventilation air.
• DO keep the appliance area clear and free from combustible
material, gasoline and other flammable vapors and liquids.
• DO examine venting system periodically and replace damaged
parts.
• DO make a periodic visual check of pilot and burners. Clean
and replace damaged parts.
• CAUTION: Pilot hole cover must be kept tightly closed during
operation.
• DO NOT use this heater if any part has been under water.
Immediately call a qualified service technician to inspect the
heater and to replace any part of the control system and any
gas control which has been under water.
• This furnace must not be connected to a chimney flue serving
a separate solid-fuel burning appliance.
IMPORTANT: This furnace has a washable permanent type
filter in the door which should be cleaned at least once per
year before the heating season. For dirty or high use areas
more frequent cleaning is required.
FAW-40SPP
FAW-40IP
40,000 (11.7)
72 1/2" (184.1mm)
14 1/8" (35.9mm)
10 3/8" (26.4mm)
1/2" (12.7mm)
4" (101mm)
4" (101mm)
275
275
SOR-1
SOK-1
ROK-1
FVE-24
FVE-34
FVE-46
DV-648
.
12427-5-0806