Keep the control compartment, logs and burner area surrounding
the logs clean.
THE LOGS CAN GET VERY HOT— HANDLE ONLY WHEN COOL.
Always keep the appliance area clear and free from combustible
materials, gasoline, and other flammable vapors and liquids.
Never obstruct the flow of combustion and ventilation air. Keep the
front of the appliance clear of all obstacles and materials.
Inspecting Venting System
A vented fireplace venting system is designed and constructed
to develop a positive flow adequate to remove flue gases to the
outside atmosphere.
Any foreign objects in the venting system, may cause spillage of
the flue gases into the room.
Periodic examination and/or cleaning of the venting system of the
solid-fuel burning fireplace must be done by a qualified service
person. visually inspect the damper and flue area for excessive
soot build-up. This soot (carbon) may be removed by brushing with
a soft bristle brush.
The Decorative Gas Log Set should be thoroughly inspected on a
regular basis at least once a year by a qualified installer.
PROBLEM OBSERVED
Gas odor during setup
Gas odor before first ignition
Delayed ignition
Incorrect burner flame
Backfire of burner
Appliance produces unwanted
odors
Logs appear to smoke
Whistle noise from appliance
35651-0-0615
MAINTENANCE & SERVICE

TROUBLESHOOTING

POSSIBLE CAUSE
Gas Leak
Gas Leak
Low gas pressure
Clogged or dirty burner ports
Blocked orifice
Incorrect gas supply or pressure
Blocked orifice
Clogged or dirty burner ports
Blocked orifice
Clogged or dirty burner ports
Low gas pressure
vapors from paint, hair spray, glues, etc.
Initial burn-off of manufacturing chemicals
Vapors from manufacturing chemicals
Air in gas line
Control knob not in fully open position
Spiral gas flex line
At the beginning of each season, the system should be checked
as follows:
1.
Check the chimney flue or vent pipe to make sure that the
flue is drawing properly, and that any vent pipe connections
are tight.
2.
Check to see that there are no blockages at the chimney or
vent termination.
3.
Check for creosote and soot build-up in chimney and/or
vents and clean if necessary.
4.
Inspect the pilot and burners (if applicable).
The burner system has been adjusted for proper operation at the
factory. No adjustment is necessary, other than altitude de-rate or
pilot flame.
NEVER enlarge valve orifices or burner ports.
Sooting
Some sooting of your log set is normal, adding to the appearance
of burned wood. If excessive sooting accumulates, clean the logs
using either of the following options::
A.
While the logs are burning and hot, spray the logs with
clean water. The soot will lift off and burn off.
B.
When the logs are cold, brush the soot off with a stiff
brush. Do not use water or soot cleaners at the same
time as a brush.
CORRECTIVE MEASURE
What To Do If You Smell Gas
• Do not try to light any appliance. • Do not touch
any electrical switch; do not use any phone
in your building. • Immediately call your gas
supplier from a neighbor's phone. Follow the gas
supplier's instructions. • If you cannot reach your
gas supplier, call the fire department.
Check gas supply pressure
Clean burner ports
Check orifice opening
Check gas supply pressure
Check orifice opening
Clean burner ports
Check orifice opening
Clean burner ports
Check gas supply pressure
Ventilate room
Ventilate room
Ventilate room
Bleed lines
Open control knob to full position
Replace gas feed line