Jandy CS250 Installation And Operation Manual - Page 11

Browse online or download pdf Installation And Operation Manual for Swimming Pool Filter Jandy CS250. Jandy CS250 16 pages. Single element cartridge pool & spa cs filters
Also for Jandy CS250: Installation And Operation Manual (16 pages)

Jandy CS250 Installation And Operation Manual
Cartridge Filters - CS Series Filter
7.
If the obstruction or debris can not be removed
or the breather tube is damaged, STOP using the
filter immediately and replace the breather tube
assembly.
WARNING
If the breather tube is not fully seated or
is damaged or clogged, trapped air can
cause the filter lid to be blown off which
can result in death, serious personal
injury or property damage.
8.
Reassemble breather tube. Fully seat the breather
tube into the bottom tank.
9.
Replace the filter locking ring/tank top assembly
on the filter and tighten (See Section 3.4 "Locking
Ring/Tank Top Assembly Installation").
10. Reopen isolation valve if they were closed.
11. Stand clear of the filter, start the pump and
circulate the water until water sprays out of the air
release valve. Close the air release valve. The filter
is now back in operating mode.
12. Watch the pressure gauge to be sure that the
pressure does not exceed 50 psi. If the pressure
approaches 50 psi, immediately turn the pump
off and clean the filter cartridges. If the pressure
remains high after cleaning the filter, refer to the
troubleshooting guide, Section 8, for possible
causes and solutions.
Section 7. Winterizing
Turn off the filter pump and switch off the circuit
1.
breaker to the pump motor.
Open air release valve on top of the filter. Do not
2.
remove.
3.
Loosen the drain nut and cap at the base of the
filter to ensure that the tank is empty.
4.
Drain circulation system of all water.
5.
Cover the system with a tarpaulin or plastic sheet
to protect it from the weather.
Page 11