Red LED
Green LED
Learn
Switch
Transceiver
PCB
Reset Switch
2.
At the J-box, slide the Learn Switch to ON. If it is
not doing so already, the AquaLink Touch screen
will display the "waiting for connection..." screen
after a maximum of 10 seconds.
3.
From the AquaLink Touch "waiting for
connection..." screen, touch the SETUP button.
The screen displays "what would you like to set?".
4.
Select "RF Channel".
what would you like to set?
RF Channel
Cancel
5.
The AquaLink Touch screen displays "select
desired RF channel, then press ENTER." Using the
arrow buttons, select the desired channel then touch
ENTER.
select desired RF channel,
then press Enter.
Cancel
6.
The AquaLink Touch screen displays "set LEARN
switch in J-Box to ON, then press J-Box RESET."
set LEARN switch in J-Box to
ON, then press J-Box RESET.
scanning...
Cancel
7.
If it is not already set to ON, set the LEARN switch
AquaLink
Touch™ and Operation Installation Manual
®
Power
Address
RF Channel
7
Enter
in J-Box to ON, then press the RESET button in the
J-Box.
8.
At the Transceiver J-Box, the Red and Green LEDs
fl ash alternately while the J-Box searches for the
correct channel.
9.
When the correct channel is found, the J-Box LEDs
fl ash simultaneously and the AquaLink Touch
screen displays "channel found! set LEARN switch
in J-Box to OFF, then press J-Box RESET."
channel found!
set LEARN switch in J-Box to
OFF, then press J-Box RESET.
10. At the Transceiver J-Box, return the Learn Switch
to OFF and press the J-Box RESET switch.
11. After a short time, the AquaLink Touch will return
to the "waiting for connection..." screen, then to
the home screen when connected successfully.
6.5.6
AquaLink Touch J-Box LED
Operation
Normal Operating Mode
Function
Reset
Both on continuous for 2
seconds
RS-485 Detected
Both rapid blink simultaneously
for 2 seconds
Waiting for AquaLink
Green LED slow blink
Touch Beacon
RS/AquaLink Touch
Random blink of both LEDS
Communication
Channel Learn Mode
Function
Searching for AquaLink
Touch channel
AquaLink Touch Channel
Learned
Power
LED Indication
LED Indication
Alternate Red/Green blink
Both blink simultaneously