The unit should be installed perpendicular to the airflow so that air passes the UV
lamps first.
Airflow
Ø
While the unit can be installed in either the return or supply air side, it may be
more effective in removing airborne contaminants if installed on the supply side.
Ø
Once a mounting location is selected, use the included Mounting Template to
mark the location of the mounting plate screw holes and Lamps/PCO Filter
insertion hole (center this hole in the duct if possible).
Ø
Drill screw holes and cut insertion hole (make sure surfaces are flat and burr
free).
Ø
Install unit into duct securing with sheet metal screws.
Ø
Open Display Panel door and insert UV lamps into UV lamp portals (swivel lamp
retaining clamps out of the way then return when lamps are inserted).
Ø
Attach white lamp socket to 4 pins on lamp base (the lamp socket is asymmetrical
and can only be attached one way – rotate socket so holes align with base pins).
(If installing into ductboard, the unit can be secured with duct tape or by making 2
sheetmetal brackets 1" x 10" and securing the unit to the brackets with screws/nuts –
another "work hole" must be cut in the duct to allow access to attach the brackets to
the mounting plate.)
CONNECT POWER
The PCO/UV N-Duct™ unit is a variable voltage device and is designed for use with
120 – 277 VAC. The unit can be plugged into any 110 VAC electrical outlet, or by cutting the
plug off the powercord can be wired into any AC source so that the unit is "ON" continually;
or wired directly into the HVAC control panel so that it operates when the HVAC system is
running.
CHECK UNIT OPERATION
Once the unit is connected to an electrical power source it should be fully operational. The
PCO/UV N-Duct™ unit has a "kill" switch activated by the Display Panel door. If the door is
open, power to the electrical functions of the unit are shut off. The Display Panel door must
be closed for the unit to operate. If the unit is receiving power and the Display Panel door is
closed, the Power On LED should be lit as well as the 2 LEDs indicating the UV lamps are lit.