Jandy Pro Series Levolor II Installation And Operation Manual - Page 8

Browse online or download pdf Installation And Operation Manual for Lighting Equipment Jandy Pro Series Levolor II. Jandy Pro Series Levolor II 20 pages. Electronic water leveler

Page 8
ENGLISH
3.3
Changing Wiring for 110 Volt
Operation
WARNING
Potentially high voltages in the Levolor control box
can create dangerous electrical hazards, possibly
causing death, serious injury or property damage.
Turn off power at the main circuit breaker providing
power to the control box to disconnect the control
box from the system. To properly and safely wire the
system, be sure to carefully follow the applicable
requirements of the National Electrical Code (NEC),
NFPA 70 or the Canadian Electrical Code (CEC),
CSA C22.1. All applicable local installation codes
must also be adhered to.
Refer to Figures 3 and 4 and do the following:
1.
Cut the splice cap connecting the black/white and
the black/red wires. See Figure 3.
2.
Connect the black/red wire with the black wire and
connect to the line side of power. See Figure 4.
3.
Connect the black/white wire with the black/
yellow wire and connect to the neutral side of
power. See Figure 4.
Transformer
6
Line
Ground
Figure 4. Modified Wiring for 110 Volt Operation
Jandy Pro Series Levolor
Models K-2000
2
1
5
Neutral
II Electronic Water Leveler
®
3.4

Grounding

Connect the green ground wire marked
grounding terminal of your electrical service or supply
panel with a continuous copper conductor having green
insulation. It must be equivalent in size to the circuit
conductors supplying this equipment, but no smaller
than No. 12 AWG (3.3mm). Refer to your local codes
for the acceptable grounding wire gauge.
|
Installation and Operation Manual
to the