KitchenAid koce500ewh01 Installation Instructions Manual - Page 6
Browse online or download pdf Installation Instructions Manual for Oven KitchenAid koce500ewh01. KitchenAid koce500ewh01 16 pages. 27" (68.6 cm) and 30" (76.2 cm) electric built-in microwave/oven combination
Mc ® E
C s n®c (xs
4-Wire
Cable
from
Home
Power
Supply
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge solid copper wire.
Electrically ground oven.
Failure to follow these instructions can result in death,
fire, or electrical shock.
IMPORTANT: Use the 4-wire cable from home power supply in the
U.S. where local codes do not allow grounding through neutral,
New Branch circuit installations (1996 NEC), mobile homes and
recreational vehicles, new construction and in Canada.
A
F
H
This oven is manufactured
with a neutral (white) power supply
wire and a cabinet-connected
green (or bare) ground wire twisted
together.
1. Disconnect
power.
2. Feed the flexible conduit from the oven through the opening
in the cabinet.
3. Remove junction box cover, if it is present.
4. Install a UL listed or CSA approved conduit connector to the
junction box.
A. UL fisted or CSA approved conduit connector
5. Route the flexible conduit from the oven to the junction box
through a UL listed or CSA approved conduit connector.
6. Tighten screws on conduit connector.
7. See "Electrical Connection
Options Chart" to complete
installation for your type of electrical connection.
C
D
A. Cable from home power supply
B. Black wires
C. Red wires
D. 4-wire flexible conduit from oven
E. Junction box
E White wires
G. UL fisted wire connectors
H. Green (or bare) ground wires
I. UL listed or CSA approved
conduit connector
1. Connect the 2 black wires (B) together using a UL listed wire
connector.
2. Connect the 2 red wires (C) together using a UL listed wire
connector.
3. Untwist white wire from green (or bare) ground wire coming
from the oven.
4. Connect the 2 white wires (F) together using a UL listed wire
connector.
5. Connect the green (or bare) ground wire (H) from the oven
cable to the green (or bare) ground wire (in the junction box)
using a UL listed wire connector.
6. Install junction box cover.
3-Wire Cable from Home Power Supply - U.S. Only
Electrical
Connection
Options
Chart
If your home has:
Go to section:
4-wire
4-Wire Cable from Home
Power Supply
IMPORTANT:
Use the 3-wire cable from home power supply
where local codes permit a 3-wire connection.
G
3-wire
3-Wire Cable from Home
Power Supply
,_
( .
)
D
E
A. Cable from home power supply
B. Junction box
C. Black wires
D. White wires
E. Green (or bare) ground wire
(from oven)
F. 4-wire flexible conduit from oven
G. Red wires
H. UL listed wire connectors
I. UL listed or CSA approved
conduit connector
6