KitchenAid 30" (76.2 CM) WALL-MOUNT CANOPY RANGE HOOD Installation Instructions Manual - Page 7

Browse online or download pdf Installation Instructions Manual for Ventilation Hood KitchenAid 30" (76.2 CM) WALL-MOUNT CANOPY RANGE HOOD. KitchenAid 30" (76.2 CM) WALL-MOUNT CANOPY RANGE HOOD 20 pages. 30” (76.2cm) sealed burner gas slide-in range with self-cleaning thermal/convection oven
Also for KitchenAid 30" (76.2 CM) WALL-MOUNT CANOPY RANGE HOOD: Installation Instructions Manual (7 pages)

KitchenAid 30
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death,
fire, or electrical shock.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that the
ground path and wire gauge are in accordance with local codes.
Check with a qualified electrical installer if you are not sure the
cooktop is properly grounded.
Make sure that the electrical connection and wire size are
adequate and in conformance with the National Electrical Code,
ANSI/NFPA 70-latest edition or CSA Standards C22.1-94,
Canadian Electrical Code, Part 1 and C22.2 No. O-M91-latest
edition, and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
Decide on the final location for the cooktop.
WARNING
Excessive Weight Hazard
Use two or more people to move and install cooktop.
Failure to do so can result in back or other injury.
1. Open product as instructed on product packaging.
2. Remove shipping materials and tape from cooktop.

Electrical Requirements

INSTALLATION INSTRUCTIONS

Prepare Cooktop

Before You Make the Electrical Connection:
To properly install your cooktop, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
A 4-wire or 3-wire, single phase, 120/240 volt, 60 Hz., AC
only electrical supply on a separate, 40-amp circuit breaker is
required for both 30" (76.2 cm) and 36" (91.4 cm) models. If a
fused system is used, fuse both sides of the line.
The cooktop should be connected directly to the junction box
through the flexible metal conduit. The flexible, armored cable
extending from the fuse box or circuit breaker box should be
connected directly to the junction box.
Locate the junction box to allow as much slack as possible
between the junction box and the cooktop so that the
cooktop can be moved if servicing becomes necessary in the
future.
A UL listed or CSA approved conduit connector must be
provided at each end of the power supply cable (at the
cooktop and at the junction box).
If the house has aluminum wiring, follow the procedure
below:
1. Connect a section of solid copper wire to the pigtail
leads.
2. Connect the aluminum wiring to the added section of
copper wire using special connectors and/or tools
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.
3. Remove vent grille.
A. Vent grille
B. Plenum
A
C
B
D
C. Removable grease filter
D. Ceramic glass top
7