Gardena FP 1400 E Operating Instructions Manual - Page 3
Browse online or download pdf Operating Instructions Manual for Water Pump Gardena FP 1400 E. Gardena FP 1400 E 13 pages. Fountain pump set gardena
The pump must not be operated when there
are people in the water. Swimming pools and
garden ponds should be designed according to
international and national design regulations.
v Please consult a professional electrician.
For Austria :
Pumps for use on swimming pools and on
ponds may only be operated via an isolating
transformer.
v Please consult a professional electrician.
For Switzerland :
In Switzerland mobile appliances which are
used outdoors, must be connected via a resi-
dual-current device.
Note :
Do not allow the pump to run without water
because dry-running leads to an undesira-
ble build up of heat.
3. Assembly
Fit the pump :
2
VARIANT 1 : Mount the
additional filter on the pump :
4
5
10
To provide a firmer mounting, the filter housing can be attached to
a solid base (e.g. paving stone).
1. Screw nozzle pipe
joint.
2. Screw the water feature insert you require (a / (b / (c / (d on
1
the nozzle pipe
All pumps
(a cascade
2
Holder for GARDENA underwater light art 7951
The additional filter can be fitted on the filter housing to extend the
maintenance interval and to give the water feature a longer life.
1. Remove the cap
2. Fit both filter shells
place.
z
3. Press sealing cover
4 a
3
You can install additional filters
Additional filters are available from GARDENA Service.
Before operating the pump, look to see if there
is any damage to the pump (esp. regarding
power cable and plug). The connection cable
of the pump cannot be replaced. If the cable is
damaged the pump must be scrapped. Ensure
that the power cable cannot be crushed if it
has not been laid in conduit in the earth or in
gravel.
Do not use the power cable to carry the pump
or to pull the plug out of the socket.
Protect the power cable from heat, oil and
sharp edges.
The temperature of the liquid used must not
be below 4 °C or above 35 °C.
Sand and other abrasive substances in the
liquid cause increased wear and reduce the
output of the pump.
Please observe the local noise prevention
regulations.
1
on to the pump with the ball and socket
1
.
art. 7650
- 7654
(b Waterbell
(c jets of
water
3
from the pump.
4
on the filter housing
3
on to the additional filter
z
4a
to increase the filter surface.
art. 7655 - 7657
(d foaming -
spring
5
and clip into
4
.