Table 3.
Other Specifications
Specification
Switch Fabric
Electrical
Specifications
Processor Module
Specifications
Extension Jack
Specifications
(206 module)
Value
Full digital, nonblocking
I
35 Watts (120 BTUs/hr.) per ACS processor module during normal power
I
consumption
45 Watts (154 BTUs/hr.) per ACS processor module during maximum
I
power consumption
10 Watts (35 BTUs/hr.) per 400 module, normal and maximum power
I
consumption
25 Watts (90 BTUs/hr.) per 206 module during normal power
I
consumption
35 Watts (120 BTUs/hr.) per 206 module during maximum power
I
consumption
30 Watts (105 BTUs/hr.) per 308EC module during normal power
I
consumption
40 Watts (140 BTUs/hr.) per 308EC module during maximum power
I
consumption
10 Watts (35 BTUs/hr.) per 1600 DSL module during normal and
I
maximum power consumption
U.S., Canada, and other 110V countries:
I
– ACS processor module and one 206 module (2-Slot carrier) = 2.3
Amps max. current, full system capacity
– ACS processor module and four 206 modules (5-Slot carrier) = 4
Amps max. current, full system capacity
Countries using 220V:
I
– ACS processor module and one 206 module (2-Slot carrier) = 1.2
Amps max. current, full system capacity
– ACS processor module and four 206 modules (5-Slot carrier) = 2
Amps max. current, full system capacity
45 days to 6 months memory backup with 2 AAA-size standard alkaline
I
batteries (IEC LR03)
68306 16 Mhz processor
I
256 Kbyte RAM
I
512 Kbyte FLASH ROM
I
Custom VLSI DSP ASIC–16 bit, 52 Mhz
I
– VLSI = Very Large Scale Integration
– DSP = Digital Signal Processor
– ASIC = Application Specific Integrated Circuit
Ringing voltage: +5 VDC, -140 VDC peak to peak; trapezoidal wave
I
shaping
35- to 38-Volt talk battery
I
Ringing frequency: 20 Hz
I
B. System Specifications
13