AEA-series
Terminal Blocks
8
7
6
5
CN1
1
2
Assembling and Installation Method
Installation method
¡ The screw should be inserted up to 6mm max from outside of
the power supply to keep a distance between inside parts and
an isolation.
¡ When two or more power supplies are used side by side, posi-
tion them with proper intervals to allow enough air ventilation.
Ambient temperature around each power supply should not
exceed the temperature range shown in "derating".
¡ Fix firmly, considering weight, though it can be used by the in-
stallation method shown in right figure.
¡ If mounting on a metal chassis, keep at least 4 mm between the
top of the power supply and the chassis for insulation between
the components and the chassis.
If the distance between the top of the power supply and the
chassis is less than 4mm, insert an insulating sheet with re-
inforced insulation between the power supply unit and metal
chassis.
The following distance is not satisfactory for cooling condition.
Please refer to "Derating" for cooling method.
AEA-4
3
4
CN2
1
2
May 25, 2021
1 AC (L) (M4)
2 AC (N) (M4)
3 Frame ground (M4)
4 - Output (M5)
5 + Output (M5)
6 Output voltage adjustable potentiometer
2
1
7 CN2 connector
8 CN1 connector
Pin Configuration and Functions of CN1, CN2
Pin No.
1
VB
Voltage Balance
2
CB
Current Balance
Matching connectors and terminals
Connector
CN1
S2B-PH-K-S PHR-2
CN2
Chassis of
customer system
Screw M4
Mounting screw
(4 pcs.)
(A)
Function
Housing
Terminal
Real : SPH-002T-P0.5S
Loose : BPH-002T-P0.5S
2.0mm
Chassis of
AEA series
6mm max
Mounting screw
(4 pcs.)
(B)
4mm min
Mfr
J.S.T.