A+ Corporation Avenger 38M Installation & Operation Instructions - Page 2

Browse online or download pdf Installation & Operation Instructions for Water Filtration Systems A+ Corporation Avenger 38M. A+ Corporation Avenger 38M 5 pages. Particulate & coalescing filter

An ISO 9001:2008 certified company

Technical Specifications

Technical Specifications
Maximum pressure rating
2,000 psig
Maximum recommended
Lowest possible pressure consistent with application
supply pressure
Maximum Liquid Block™
35 psig*
*Slowly open the supply pressure so that the minimum differential
valve auto-reset pressure
pressure required to shut off the Liquid Block™ is not met or exceeded.
Maximum temperature
185˚F (85˚C) for Type 6 membrane
302˚F (150˚C) for Type 7 membrane
1,000 cc/min for Type 6 membrane
Maximum recommended
membrane flow rate
3,600 cc/min for Type 7 membrane
(For higher flow rates contact the factory)
*Maximum flow results in approximately 2 psi membrane differential pressure
Element size
Outside Diameter: ~ 1.4"
Inside Diameter: ~ 1.0"
Length: ~ 2.5"
Port sizes
1/4" female NPT
5
Number of ports
Internal volume
50 cc
Wetted materials
Machined parts: 316/316L stainless steel / NACE compliant
All other metal parts: stainless steel / NACE compliant
Sealing material: Fluoroelastomer standard
Membrane: inert
Dimensions
Back View
2.626"
1.876"
1.250"
DIA.
3.700"
3.256"
0.883"
Side View
MINIMUM MAINTENANCE CLEARANCE 8.100"
3.700"
PORT D
OPTIONAL
MOUNTING
BRACKET
2
4.995"
4.270"
2.625"
2.000"
0.355"
©
2005 A+ Corporation, LLC. All rights reserved.
SCC-38M-InsInstallationOperation_100318