Garmin 500W Series Instructions Manual - Page 18

Browse online or download pdf Instructions Manual for GPS Garmin 500W Series. Garmin 500W Series 26 pages. Continued airworthiness
Also for Garmin 500W Series: Pilot's Manual Addendum (24 pages), Supplemental Flight Manual (17 pages), Pilot's Manual Addendum (50 pages), Quick Reference (25 pages), Instructions Manual (11 pages), Instructions Manual (23 pages)

Garmin 500W Series Instructions Manual
Alert Text
CDI key stuck
CDI key disabled
Check unit cooling
COM has failed (420W and
430W only)
COM is not responding
(420W and 430W only)
COM needs service
(420W and 430W only)
COM push-to-talk key stuck
(420W and 430W only)
COM remote transfer key is
stuck (420W and 430W only)
COM transfer key stuck
(420W and 430W only)
COM transmitter power has
been reduced (420W and
430W only)
Configuration error - Config
service req'd
Data transfer cancelled
(crossfill is busy)
Data transfer cancelled (data
invalid)
400W Series
Instructions for Continued Airworthiness Bell 407
Possible Cause
 The CDI key is stuck in the enabled
(or "pressed") state. Try pressing the
CDI key again to cycle its operation.
 "Ignore CDI key" has been selected
on the MAIN CDI/OBS CONFIG
page.
 The 400W Series unit has detected
excessive display backlighting
temperature. The backlighting has
been automatically dimmed to
reduce the temperature.
 The unit has detected a failure in its
communications transceiver.
 Internal system-to-system
communication between the main
processor and the COM transceiver
has failed. Operational status of the
COM transceiver is unknown.
 The unit has detected a failure in its
communications transceiver. The
COM transceiver may still be usable.
 The external push-to-talk (PTT)
switch is stuck in the enabled (or
"pressed") state.
 Wiring is incorrect.
 The remote COM transfer switch is
stuck in the enabled (or "pressed")
state.
 The COM flip-flop key is stuck in the
enabled (or "pressed") state.
 The unit has detected excessive unit
temperature. The COM transceiver
transmit power has been
automatically reduced to compensate
for the condition.
 Insufficient voltage level
 The configuration information has
been lost or corrupted.
 An attempt to transfer flight plan data
during a unit-to-unit crossfill was
cancelled.
 An attempt to transfer a single user
waypoint during a unit-to-unit crossfill
was cancelled. No waypoint was
specified on the Crossfill Page.
Solution
 Contact Garmin technical
support.
 Go to the MAIN CDI/OBS
CONFIG page and deselect
"Ignore CDI key"
 Check for adequate ventilation
or check cooling airflow. Refer to
Section 2.7 of the Installation
Manual.
 Contact Garmin technical
support.
 Contact Garmin technical
support. If the COM board is still
working, it will automatically tune
to 121.500 MHz. Transmit and
receive functions may still
operate regardless of the
displayed frequency.
 Contact Garmin technical
support
 Try pressing the PTT switch
again to cycle its operation.
 Check Wiring
 Try pressing the switch again to
cycle its operation.
 Verify the wiring is correct.
 If the message persists, contact
Garmin technical support.
 Try pressing the switch again to
cycle its operation.
 If the message persists, contact
Garmin technical support.
 Check for adequate ventilation
or check cooling airflow. Refer to
Section 2.7 of the Installation
Manual.
 Check the input voltage
 Reconfigure the unit
 The host unit is busy. Wait until
any previous crossfill operation
is complete, before reattempting
the transfer.
 Select a user waypoint and re-
attempt the transfer.
190-01226-14 Rev. 3
Page 18 of 26