2-Channel High Speed AD Module AN9238 User Manual
The following table is the voltage comparison table after analog input signal
to AD8138 differential output:
AD Analog
Input Value
-5 V
0 V
+5 V
Part 2.4: AD9238 Conversion
The default AD is configured as offset binary, and the value of AD
conversion is shown in the figure below:
7/17
AD8065 Operational
Amplifier Output
-1 V
0 V
+1 V
AD8138 Differential Output
(VIN+−VIN−)
-1 V
0 V
+1 V