4.

Operation

Switching on the pump
Pressing the ON / OFF button (1, Fig. 3) switches
the VELOX Hydraulic Pump on or off.
I
ON =
O
OFF =
ON /
OFF
1
Pressure adjusting
valve (spindle)
4.1

Setting the torque

Use the enclosed torque chart to determine the
necessary pressure of the VELOX Hydraulic Pump.
Turn on the motor (1), press the remote control button
(man) and hold.
Simultaneously adjust the spindle (3) until the desired
pressure is displayed on the gauge (2). Depress the
remote control button (man), block spindle (3) and
thus secure it against independent twisting (Fig. 3-4).
VELOX
Gauge
2
3
Fig. 3
electrical hydraulic pump
4.2

Manual operation with remote control

- Manual operation with button (man)
Fig. 4
After turning on the motor and determining the
desired torque (using the enclosed torque chart), a
rotating movement of the hydraulic torque drive is
reached by pressing and loosening the remote control
button (man), resulting in the corresponding torque.
Keep pressing the remote control button (man) until
the drive of the hydraulic wrench stops turning and
the pre-set pressure is reached. Please note display
of gauge (2).
Then press the remote control button (man) once or
twice again, until the pre-set pressure is reached to
make sure that the final torque is achieved at the bolt
connection and the hydraulic torque wrench does not
stop until it reaches the stop of the hydraulic piston.
Note hint, page 9, item 10
Please note display of gauge (2) on the VELOX
Hydraulic Pump to make sure the pre-set pressure
has been reached (Fig 3).
The bolting connection will be loosened completely
by loosening the bolting connection repeatedly.
7
(man)
Manuell