alkitronic CLD 225 Operating And Maintenance Manual - Page 3

Browse online or download pdf Operating And Maintenance Manual for Tools alkitronic CLD 225. alkitronic CLD 225 12 pages. Compact torque multiplier

A
Incoming goods inspection and packaging
All parts must be visually inspected for possible
transport damage. If damage is found, notify the
carrier immediately. Returns only in original pack-
aging, by doing so damage is avoided. Therefore,
keep the packaging!
Type CLD
R = Rotatable
Type CLS
S = Rigid
Pneumatic Torque Multiplier
alkitronic® CLD
Compact torque multiplier
Torque up to approx. 7,225
ft.lbs, clockwise / anti-clock-
wise rotation, optional po-
sitioning of the control unit
thanks to rotatable mounting.
alkitronic® CLS
Compact torque multiplier
Fast rotating assembly mul-
tiplier. A secure support for
the reaction torque must be
ensured!
Torques up to approx. 1,070
ft.lbs, clockwise / anti-clock-
wise rotation.
B
General description
The torque can be regulated via the air supply or via the
pressure regulator of a maintenance unit. The accuracy of the
torque depends on the stability of the air supply. An air pres-
sure of 3-7 bar (43-10,000 psi) at a flow rate of approx. 10-15
l/sec (122-915 cu.in./min) guarantee optimum working even
in explosion-protected working areas.
Type CLS2
Type RCL
3
alkitronic® CLS2
2 gear compact torque multiplier
Torques up to approx.
35,855 ft.lbs, 2 gears (overdrive/
power gear), right / left rotation.
alkitronic® RCL
2 gear radial compact torque
multiplier
For use on protruding screw
ends such as plate heat ex-
changers. Torques up to ap-
prox. 3,390 ft.lbs, 2 gears.