Garmin Boat Switch Installation Instructions Manual - Page 8
Browse online or download pdf Installation Instructions Manual for Marine Equipment Garmin Boat Switch. Garmin Boat Switch 27 pages. Pre-configured digital switching system
Wire Label
CH 9-TOGGLE 6(10A)
CH 10-TOGGLE 7(10A)
CH 11-LIVEWELL(10A)
CH 12-BILGE 1
MANUAL(10A)
CH 13-BILGE 2
MANUAL(10A)
CH 14-BILGE 1
MONITOR
CH 15-BILGE 2
MONITOR
X1 Breakout Wire Connections
The breakout wires on the X1 wiring harness allow you to add a physical switch to a device or circuit connected
to a digital switch on the specified primary wires of the X1 and X2 wiring harnesses. Connecting these wires to
the CH 32 TANK SENSOR GROUND wire on the X2 breakout wiring harness through a physical momentary
switch triggers the associated latching, dimming, or momentary switch for devices connected to the correlated
channels on the primary harnesses.
NOTE: Only momentary switches should be used for physical switches. Using physical latching or toggle
switches can override the Garmin Boat Switch device and disable digital switching on that channel through the
connected Garmin chartplotter.
Wire Label
SWITCH INPUT: CH1
TOGGLE 1 (OPTIONAL)
SWITCH INPUT: CH2
TOGGLE 2 (OPTIONAL)
SWITCH INPUT: CH3
TOGGLE 3 (OPTIONAL)
1
All switches on the Garmin Boat Switch device must be configured in the chartplotter software to function properly
8
Wire
Wire Color
Gauge
Gray with
14 AWG
black stripe
Blue with
14 AWG
black stripe
Orange
with black
14 AWG
stripe
Brown
14 AWG
Brown
14 AWG
Brown with
16 AWG
black stripe
Brown with
16 AWG
black stripe
Wire
Wire
Color
Gauge
Black
18 AWG
Brown
18 AWG
Red
18 AWG
Software
Wire Function
Fuse Rating
10A
Provides a latching switch output
10A
Provides a latching switch output
Provides a latching switch output for a live-
10A
well pump
Provides a latching switch output for a bilge
10A
1
pump
.
Provides a latching switch output for a bilge
10A
1
pump
.
Input for monitoring bilge pump 1 automatic
operation. Generates an alarm when the
N/A
pump runs for longer than 2 min. or is
activated five times within 60 min. (12 Vdc)
Input for monitoring bilge pump 2 automatic
operation. Generates an alarm when the
N/A
pump runs for longer than 2 min. or is
activated five times within 60 min. (12 Vdc)
Wire Function
Latching switch input for CH 1-TOGGLE 1(5A) on this
wiring harness.
By default this input is tied to CH 2-TOGGLE 2(5A) for
navigation-light control
Wiring, page
12).
Latching switch input for CH 2-TOGGLE 2(5A) on this
wiring harness.
By default this input is tied to CH 1-TOGGLE 1(5A) for
navigation-light control
Wiring, page
12).
Latching switch input for CH 3-TOGGLE 3(5A) on this
wiring harness.
1
.
1
.
1
.
(Navigation and Anchor Light
(Navigation and Anchor Light
(Switch Configuration, page
18)