SWING OPERATION

Begin air conditioner operation before performing this procedure.
To select Vertical airflow SWING Operation
Press the AIR FLOW DIRECTION VERTICAL SWING button .
The SWING indicator lamp (VERTICAL SWING) (orange) will light.
In this mode, the UP/DOWN air direction flaps will swing automatically to direct the
air flow both up and down.
To Stop Vertical airflow SWING Operation
Press the AIR FLOW DIRECTION VERTICAL SWING button
once again.
The SWING indicator lamp (VERTICAL SWING) will go out.
Airflow direction will return to the setting before swing was begun.
About Swing Operation
G The range of swing is relative to the currently set airflow
direction.
Air flow direction set
1
2
3
4
5
6
7
Air direction range (See page 11, Fig. 8)
To select Horizontal airflow SWING Operation
Press the AIR FLOW DIRECTION HORIZONTAL SWING button.
The SWING indicator lamp (HORIZONTAL SWING) (orange) will light.
In this mode, the RIGHT/LEFT air direction louvers will swing automatically to direct
the airflow both right and left.
To Stop Horizontal airflow SWING Operation
Press the AIR FLOW DIRECTION HORIZONTAL SWING button
once again.
The SWING indicator lamp (HORIZONTAL SWING) will go out.
Airflow direction will return to the setting before swing was begun.
About Swing Operation
G The range of swing is relative to the currently set airflow
direction.
Air flow direction set
1
2
3
4
5
Air direction range (See page 11, Fig. 9)
12
Range of swing
1 to 3
1 to 4
2 to 5
3 to 6
4 to 7
5 to 7
1 to 7 (All range)
Range of swing
1 to 5 (All range)
1 to 3
2 to 4
3 to 5
1 to 5 (All range)
Example: When set to vertical swing.
G If the swing range is not as desired, use the remote con-
trol unit's AIR FLOW DIRECTION VERTICAL SET button to
change the range of swing.
G The SWING operation may stop temporarily when the air
conditioner's fan is not operating, or when operating at
very low speeds.
G During use of the Cooling and Dry modes, do not set the
air UP/DOWN direction flaps, in the Heating range (5 to
7) for long periods of time, since water vapor may con-
dense near the outlet louvers and drops of water may
drip from the air conditioner.
Example: When set to horizontal swing.
G If the swing range is not as desired, use the remote con-
trol unit's AIR FLOW DIRECTION HORIZONTAL SET but-
ton to change the range of swing.
G The SWING operation may stop temporarily when the air
conditioner's fan is not operating, or when operating at
very low speeds.
SET
SWING
SET
SWING
TIME
TEST
ENERGY
ADJUST
RUN ACL
SAVE
SET
SWING
SET
SWING
TIME
TEST
ENERGY
ADJUST
RUN ACL