Conversion from Natural Gas to LPG
It is important to note that this model is designed for use with natural gas
but can be converted for use with butane or propane gas providing the
correct injectors are fitted. The gas rate is adjusted to suit.
Method
1) Ensure that the gas taps are in the 'OFF' position
2) Isolate the hob from the electricity supply
3) Remove all pan supports, burner caps, rings, crowns and control knobs.
4) With the aid of a 7mm box spanner the burner injectors can then be
unscrewed and replaced by the appropriate LPG injectors.
TO ADJUST THE GAS RATE
With the aid of a thin bladed screwdriver completely tighten down the
by pass adjustment screw. Upon completion stick the replacement
rating plate on the under side of the hob.
IMPORTANT
The replacement/conversion of the gas hob should only be
undertaken by a competent person