AEG 34942G Operating And Installation Instructions - Page 12
Browse online or download pdf Operating And Installation Instructions for Hob AEG 34942G. AEG 34942G 27 pages. Gas hobs
Also for AEG 34942G: Operating And Installation Instructions (26 pages), Operating And Installation Manual (26 pages), Operating And Installation Instructions (26 pages), Operating And Installation Instructions (26 pages)
Instructions for the Installer
Engineers technical data
OVERALL DIMENSIONS
CUT OUT DIMENSIONS
SUPPL Y CONNECTIONS Gas:
IGNITION HT SPARK
HEAT INPUT
Rear Left Burner (semi rapid)
Front Left Burner (rapid) 3.0 kW Natural Gas (10236 BTU/HR)
Central Burner (triple-crown)
Rear Right Burner (semi rapid) 2.0 kW (6824 BTU/HR)
Front Right Burner (auxiliary) 1.0 kW (3412 BTU/HR)
APPLIANCE CLASS
APPLIANCE CA TEGORY
GAS SUPPLY
12
Width:
Depth:
Height:
Weight:
Width:
Depth:
Thickness: 30 mm
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230-240V 50Hz supply, 3 core flexible cable with
non rewireable plug fitted with a 3 amp cartridge fuse.
Spark Generator
Ispra Control's BF 50066 - 230-240V 0.6 YA T120
Spark Gap : Fixed
2.0 kW (6824 BTU/HR)
2.8 kW L.P.G. (9554 BTU/HR)
4,0 kW (13652 BTU/HR)
3
II2H3+
Natural gas G20 / 20 mbar
860 mm
500 mm
88 mm
16 Kg
830 mm
470 mm