Electrical connections
The appliance is designed to be connected to 230 V monophase 50 Hz AC
220 V, 60 Hz electrical supply.
The connection must be carried out in compliance with the laws and
regulations in force.
Before the appliance is connected:
1) check that the main fuse and the domestic installation can support the load
(see the rating label);
2) check that the power supply is properly earthed in compliance with the
current rules;
3) check the socket or the double pole switch used for the electrical connection
can be easily reached with the appliance built in the forniture unit.
The appliance is supplied with a connection cable. This has to be provided with
a proper plug, able to support the load marked on the identification plate. The
plug has to be fitted in a proper socket.
If connecting the appliance directly to the electric system, it is necessary that
you install a double pole switch between the appliance and the electricity
supply, with a minimum gap of 3 mm. between the switch contacts and of a type
suitable for the required load in compliance with the current rules.
The connection cable has to be placed in order that, in each part, it cannot reach
a room temperature higher than 50°C.
The brown coloured phase cable (fitted in the terminal block contact marked
with "L") must always be connected to the network phase.
REPLACEMENT OF THE VOLTAGE CABLE
The connection of the voltage cable to the appliance's terminal block is of type
"Y". This means that its replacement requires the specific equipment of a
technician.
The connection of the voltage cable to the appliance's terminal block is of type
"Y". This means that its replacement requires the specific equipment of a
technician.
In this case, only cable type H05 V2V2-F T90 must be used. The cable section
must be suitable to the voltage and the working temperature.
The yellow/green earth wire must be approximately 2 cm. longer than the phase
wires.