AEG 35944G Operating And Installation Instructions - Page 12

Browse online or download pdf Operating And Installation Instructions for Hob AEG 35944G. AEG 35944G 26 pages. Gas hobs
Also for AEG 35944G: Operating And Installation Manual (26 pages), Operating And Installation Instructions (26 pages), Operating And Installation Instructions (26 pages), Operating And Installation Instructions (27 pages)

AEG 35944G Operating And Installation Instructions

Instructions for the Installer

Engineers technical data

OVERALL DIMENSIONS Width:
CUT OUT DIMENSIONS
SUPPLY CONNECTIONS Gas:
IGNITION HT SPARK
HEAT INPUT
Rear Left Burner (semi rapid)
Front Left Burner (rapid)
Central Burner (double-crown)
Rear Right Burner (semi rapid)
Front Right Burner
APPLIANCE CLASS
APPLIANCE CATEGORY
GAS SUPPLY
12
Depth:
Height:
Weight:
Width:
Depth:
Thickness:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230-240V 50Hz supply, 3 core flexible cable with
non rewireable plug fitted with a 3 amp cartridge fuse.
Spark Generator
Ispra Control's BF 50066 - 230-240V 0.6 YA T120
Spark Gap : Fixed
(auxiliary)
3
II2H3+
Natural gas G20 / 20mbar
860 mm.
500 mm.
88 mm.
8 Kg.
830 mm.
470 mm.
30 mm.
2.0 kW (6824 BTU/HR)
3.0 kW Natural Gas (10236 BTU/HR)
2.8 kW L.P.G. (9554 BTU/HR)
3,5 kW (11942 BTU/HR)
2.0 kW (6824 BTU/HR)
1.0 kW (3412 BTU/HR)