AEG 6531 DG-M Instruction And Installation Book - Page 12
Browse online or download pdf Instruction And Installation Book for Hob AEG 6531 DG-M. AEG 6531 DG-M 24 pages.
Type of gas
Adjusted to natural gas: G20-20 mbar
Category and pressures
UK: II
20 mbar - 28/37 mbar
2H3+
Max. nominal load Q na H
Medium sized burner =
Large sized burner =
Total=
FSD
The unit features fully-secured gas
taps (thermo-fuse).
H
= Top calorific value
S
Q = Nominal load
ID. CE-048BO-0037
Ignition transformer= 50 HZ - 0,6 VA
Radio-noise reduction
This unit observes the current EEC-
directive on radio noise reduction.
This gas appliance is
marked in accordance with the gas
appliance Directive (90/396/CEE), the
low voltage directive (73/23/CEE) and
the EMC directive (89/336/CEE incl.
the agreed directive changes.
Cable type 0,75 mm² HO5 V2V2-F
Technical data
:
S
1,9 kW x 1
3,0 kW x 1
4,9 kW
-approved and
N
The hob must be connected via an
external switch with a contact
gap of min. 3 mm (the main switch
may be used)
Wiring
Blue and brown: 51 mm +/- 3 mm
Yellow/Green: 61 mm +/- 3 mm
12
240 V
1N + PE
L1
HO5V2V2-F