Permanent Connection

In the case of a permanent connection, it is necessary that you install
a double pole switch between the hob and the electricity supply
(mains), with a minimum gap of 3 mm. between the switch contacts
and of a type suitable for the required load in compliance with the
current electric regulations.
The switch must not break the yellow and green earth cable at any
point.
Ensure that the hob supply cord does not come into contact with
surfaces with temperatures higher than 50 deg. C.

Wiring diagram

N
1
L
1. TAPS IGNITOR SWITCHES
2. IGNITOR UNIT
1
220
240
2
3
0
4
2
21