AEG 95601 G Operating And Installation Instructions
BURNER
TYPE OF GAS
POSITION
NOMINAL THERMAL
POWER
NATURAL GAS
NOMINAL FLOW
20 mbar
VALUE =
RATE
37.78 MJ/m
3
NOZZLE REFERENCE
3
Ws - 50.7 MJ/ m
1/100 mm
NOMINAL THERMAL
LPG GAS
POWER
28-30/37 mbar
NOMINAL FLOW
VALUE =
RATE
49.92 MJ/Kg
NOZZLE REFERENCE
1/100 mm
Burner
Dia. Tap By-pass
1/100 mm
Auxiliary
Semi-rapid
Rapid
Aeration adjustment none
RAPID
(large)
MAX
MIN
kW
2.9
0.65
m
3
/h
0.276
0.062
119
Adjust.
kW
2.7
0.65
g/h
195
46.8
86
40
Tap colour
28
Red/Red
32
Blue/Blue
40
Black/Black
SEMI-RAPID
AUXILIARY
(medium)
(small)
MAX
MIN
MAX
1.9
0.45
1.0
0.181
0.043
0.095
0.031
96
Adjust.
70
Adjust.
1.9
0.45
1.0
137
32.4
72
71
32
50
MIN
0.33
0.33
23.8
28
13