Instructions for the Installer

Engineers technical data

Overall dimensions
Width:
Depth:
Cut out dimensions
Width:
Depth:
Supply Connections
Gas: RC 1/2 inch (1/2 inch male) Rear right
hand corner
Electric: 230-240V 50Hz supply, 3 core flexible
cable with non rewireable plug fitted with a 3 amp
cartridge fuse.
Ignition HT Spark
Spark Generator: Ispra Control's BF 50066 -
230-240V 0.6 YA T120
Spark Gap : Fixed
TYPE OF GAS
NOMINAL THERMAL
NATURAL GAS
POWER (kW)
20 mbar
NOMINAL FLOW
VALUE =
RATE (m
37.78 MJ/m
3
NOZZLE REFERENCE
Ws - 50.7 MJ/ m
3
(1/100 mm)
NOMINAL THERMAL
LPG GAS
POWER (kW)
28-30/37 mbar
NOMINAL FLOW
VALUE =
RATE (g/h)
49.92 MJ/Kg
NOZZLE REFERENCE
(1/100 mm)
880 mm
510 mm
830 mm
480 mm
BURNER
ULTRA-RAPID
(triple crown)
POSITION
M A X
3.8
/h)
0.362
3
146
3.8
274
98
Burner
Dia. Tap By-pass
Auxiliary
Semi-rapid
Ultra-rapid
Aeration adjustment none
Heat Input
Ultra-rapid Burner 3.8 kW Natural Gas
(Triple crown)
(12,966 BTU/HR)
3.8 kW L.P.G.
(12,966 BTU/HR)
Semi-rapid Burner 1.9 kW (6,483 BTU/HR)
Auxiliary Burner
1.0 kW (3,412 BTU/HR)
Appliance class
Appliance category
Gas supply
Natural gas G20 / 20mbar
SEMI-RAPID
(medium)
MIN
M A X
1.20
1.9
0.114
0.181
Adjust.
96
1.20
1.9
86
137
40
71
Instructions for the Installer
1/100 mm
28
32
56
II2H3+
AUXILIARY
(small)
MIN
M A X
MIN
0.45
1.0
0.33
0.043
0.095
0.028
Adjust.
70
Adjust.
0.45
1.0
0.33
32.4
72
23.8
32
50
28
3
11