Fujitsu Primergy BX620 S2 System Configuration And Order-Information Manual - Page 13
Browse online or download pdf System Configuration And Order-Information Manual for Server Fujitsu Primergy BX620 S2. Fujitsu Primergy BX620 S2 18 pages.
PRIMERGY BX620 S2 / BX620 S3
FC Switch Blade
Data Sheet
Type
Base Unit
CTO optional
Fibre Channel
Internal
Interfaces
External
Dimensions (W x D x H (mm) )
*1. This is the type of FC Switch Blade which is mounted on Network Blade Slot 3 of BX600 S2 Blade Server System Unit.
*2. This is the type of FC Switch Blade which is mounted on Network Blade Slot 4 of BX600 S2 Blade Server System Unit.
When FC Switch Blade (PGBFCS1022) is ordered, FC Switch Blade (PGBFCS102) or FC Pass-Thru Blade (PGBFCB101) should be ordered at a time.
*. The max number of available ports under initial condition is as follows.
internal : 8ports
external : 4ports
If it is necessary to connect more than 8 BX620 S2/BX620 S3, FCSW Upgrade kit:Porton Demand(PG-FCSU102) is required to increase available ports.
*. When FC Switch Blade (PG-FCS102) are mounted on Network Blade Slot 3,4 of BX600 S2 Blade Server System Unit (PGUR3SC1),
the card on Expansion Board Slot of BX620 S2 / BX620 S3 should be 2Gbit/s FC I/O Module (PG-FCD102).
BX620 S2 / BX620 S3 with 1Gbit/s Ethernet I/O Module (PG-LND101) and BX620 S2 / BX620 S3 with 2Gbit/s FC I/O Module (PG-FCD102)
are not allowed to be mounted together on same BX600 S2 Blade Server System Unit (PGUR3SC1).
*. SFP Module (PG-SFPS02), whose number is same as that of used external ports, should be ordered.
FC Pass-Thru Blade
Data Sheet
Type
Base Unit
CTO optional
Fibre Channel
Internal
Interfaces
External
Dimensions (W x D x H (mm) )
*1. This is the type of FC Pass-Thru Blade which is mounted on Network Blade Slot 3 of BX600 S2 Blade Server System Unit.
*2. This is the type of FC Pass-Thru Blade which is mounted on Network Blade Slot 4 of BX600 S2 Blade Server System Unit.
When FC Pass-Thru Blade (PGBFCB1012) is ordered, FC Switch Blade (PGBFCS102) or FC Pass-Thru Blade (PGBFCB101) should be ordered at a time.
*3. Connections between internal ports and external ports are one-to-one.
*. When FC Pass-Thru Blade (PG-FCB101) are mounted on Network Blade Slot 3,4 of BX600 S2 Blade Server System Unit (PGUR3SC1),
the card on Expansion Board Slot of BX620 S2 / BX620 S3 should be 2Gbit/s FC I/O Module (PG-FCD102).
BX620 S2 / BX620 S3 with 1Gbit/s Ethernet I/O Module (PG-LND101) and BX620 S2 / BX620 S3 with 2Gbit/s FC I/O Module (PG-FCD102)
are not allowed to be mounted together on same BX600 S2 Blade Server System Unit (PGUR3SC1).
*. SFP Module (PG-SFPS01), whose number is same as that of used external ports, should be ordered.
8ports (4Gbps) ( 10ports (4Gbps when FCSW Upgrade kit:Porton Demand (PG-FCSU102) is applied )
4ports (4Gbps, Fibre Channel) ( 6ports (4Gbps, Fibre Channel) when FCSW Upgrade kit:Porton Demand (PG-FCSU102) is applied )
FC Pass-Thru Blade
PG-FCB101
PGBFCB101 (*1) / PGBFCB1012 (*2)
10ports (2Gbps) (*3)
10ports (2Gbps,Fibre Channel) (*3)
35 x 250 x 130
FC Switch Blade
PG-FCS102
PGBFCS102 (*1) / PGBFCS1022 (*2)
35 x 250 x 130